Digital non-glass pH sensor
Ceramax CPS341D
Memosens enamel electrode for food and life sciences industries
Ceramax CPS341D is the long runner for hygienic applications in food and life sciences industries. The sensor guarantees long-term stability and lowest maintenance wherever it is applied. Thanks to Memosens digital sensor technology, CPS341D combines maximum process and data integrity with simple operation. It resists corrosion and moisture, enables lab calibration and facilitates predictive maintenance.
- F
- L
- E
- X
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Specs at a glance
-
Measurement range
pH -2 to 14
-
Process temperature
0 to 140 °C
(32 to 280 °F) -
Process pressure
0 to 7 bar abs
(0 to 101.5 psi)
-
Quick selection
Individual configuration
-
Benefits
Long-term stability over many years
Hygienic design: Suitable for cleaning in place (CIP) and sterilization in place (SIP)
High mechanical stability due to pH-sensitive enamel on a steel carrier
Insensitive to soiling thanks to large pH measuring surface
...
-
Field of application
Food production, also highly pasty media
Beverage production and filling
Life sciences:
- Water treatment
- Active ingredient production
- Active ingredient preparation
- Biotechnology
Documents / Manuals / Software
-
Technical Information CPS341D
Electrode with pH sensitive enamel and digital Memosens technology
Technical Information (TI) -
Ceramax CPS341D
Operating Instructions
Sensor with pH-sensitive enamel and digital Memosens technology
Operating Instruction (BA) -
Ceramax CPS341D
Sicherheitshinweise für elektrische Betriebsmittel im
explosionsgefährdeten Bereich
Safety instructions for electrical apparatus for explosion-hazardous
areas
Conseils de sécurité pour matériels électriques destinés aux zones
explosibles
Safety Instructions
Safety instructions for electrical apparatus for explosion-hazardous
areasEx Safety Instructions (XA) -
Manufacturer Declaration
TSE/BSE free
Certificate (ZE) -
Satisfaction guaranteed with Ceramax CPS341D
The new hygiene standard for pH measurement
Publications (PU)06/10English -
Wunschlos glücklich mit Ceramax CPS341D
Der neue hygienische Standard für die pH-Messung
Publications (PU)06/10German -
Kompetenz in der Flüssigkeitsanalyse
Vom Sensor bis zur schlüsselfertigen Komplettlösung
Fields of Activities (FA)03/19German -
Expertise in liquid analysis
From sensors to complete turnkey solutions
Fields of Activities (FA)03/19English -
Catálogo Portfolio Analítica
Desde sensores hasta soluciones completas
Fields of Activities (FA)01/17Spanish -
Esperti nell’analisi dei liquidi
Dai sensori singoli a soluzioni
complete “chiavi in mano”Fields of Activities (FA)01/17Italian -
Jistota v analýze kapalin
Od senzorů po kompletní dodávku na klíč
Fields of Activities (FA)01/17Czech -
pH 測定セレクションガイド
産業プロセスにおける pH 測定
Competence Brochure (CP)08/15Japanese -
CP00010C pH measurement in industrial processes for US market
Selection and engineering guide for your industry and application
Competence Brochure (CP)04/15English -
Measurement and control aspect of pH using inductively coupled with
bidirectional Memosens technology in flue gas desulfurization process
White Paper CP971C pH measurement and control in a power utility is an
integral part of process. The scrubber efficiency is highlydependent on
the pH. Numerous opportunities were revealed for saving time, as well as
the cost and materials in power plants. In afossil fuel power plant,
the
chemical energy stored in coal, oil, natural gas, shale oil, oxygen and
air
is converted into thermal, mechanical and finally into electrical
energy. In
other words, water is heated to steam, which spins a steam turbine. The
steam turbine drives an electrical generator.Competence Brochure (CP)04/11English -
pH-Messung in Industrieprozessen
Auswahl- und Engineering-Hilfe für verschiedene Industriebranchen und
ApplikationenCompetence Brochure (CP)03/20German -
pH measurement in industrial processes
Selection and engineering guide for different industries and
applicationsCompetence Brochure (CP)02/20English -
CP01202C pH Sensors:Calibrate, clean, perform a calibration check
or...?
This white paper will address
Knowing when to do a pH sensor calibration versus a calibration
check
How to properly clean a pH sensor
How to perform a pH sensor calibration
A decision tree for step by step guidanceCompetence Brochure (CP)02/12English -
Focus on the food industry
The best product fit for your
applicationsCompetence Brochure (CP)01/16English -
Ceramax CPS341D
Shatterproof electrode with pH sensitive
enamel and Memosens technology
American version: pH electrode in hygienic design for demanding
measuring
locations in food and pharmaceutical industryInnovations (IN)08/12English -
Ceramax CPS341D
Shatterproof electrode with pH sensitive
enamel and Memosens technology
pH electrode in hygienic design for demanding measuring
locations in food and pharmaceutical industryInnovations (IN)06/10English -
Ceramax CPS341D
Bruchsichere Elektrode mit pH-empfindlichem
Email und Memosens-Technologie
pH-Elektrode im hygienischen Design für anspruchsvolle
Messungen in Lebensmittel- und PharmaindustrieInnovations (IN)06/10German -
Memosens digital sensor technology for liquid analysis
(mp4 format, 61.7 MB)
De Memosens technologie van Endress+Hauser is een revolutie in
vloeistofanalyse.
Het zet een analoge meetwaarde om in een digitaal signaal dat geheel
galvanisch
gescheiden naar de transmitter gaat.
Memosens sensoren slaan kalibratie-, sensor- en procesdata op in hun
interne
geheugen. Dit zorgt voor een juiste processturing en optimaal onderhoud.Animation11/15fr -
Memosens digital sensor technology for liquid analysis
(mp4 format, 61.7 MB)
La technologie Memosens Endress et Hauser révolutionne l'analyse
physico-
chimique. Elle convertit les valeurs mesurées en signaux numériques et
les transfère
au transmetteur via une connexion sans contact.
Les capteurs Memosens mémorisent les données d'étalonnage, de capteur et
de
process, ce qui permet un contrôle précis du process et une maintenance
optimale.Animation11/15fr -
Memosens digital sensor technology for liquid analysis
(mp4 format, 61.7 MB)
Memosens converts the measured value to a digital signal and transfers
it to the transmitter without a contacting connection.
This video shows how it works and how people in process analytics
profit from it.Animation08/15English -
Memosens digital sensor technology for liquid analysis
(flv format, 17.2 MB)
Memosens converts the measured value to a digital signal and transfers
it to the transmitter without a contacting connection.
This video shows how it works and how people in process analytics
profit from it.Animation08/15English -
Memosens - Digitale Sensortechnologie für die Flüssigkeitsanalyse
(flv-Format, 17.8 MB)
Memosens digitalisiert den Messwert im Sensor und überträgt ihn
kontaktlos zum Messumformer.
Dieses Video zeigt, wie Memosens funktioniert und wie PAT-Mitarbeiter
davon profitieren.Animation08/15German -
Tecnología Memosens - Fácil, segura y sencilla (mp4-Format, 61.7 MB)
La tecnología Memosens de Endress+Hauser ha revolucionado el análisis de
líquidos.
Convierte el valor medido en una señal digital, y la transfiere por
inducción al transmisor.Animation08/15Spanish -
Memosens - Digitale Sensortechnologie für die Flüssigkeitsanalyse
(mp4-Format, 61.7 MB)
Memosens digitalisiert den Messwert im Sensor und überträgt ihn
kontaktlos zum
Messumformer.
Dieses Video zeigt, wie Memosens funktioniert und wie PAT-Mitarbeiter
davon
profitieren.Animation08/15German -
CPS341Z-D5 (Croatia)
Electrolyte for CPS341D
Electrolytes -
CPS341Z-D5 (Ireland)
Electrolyte for CPS341D
ElectrolytesEnglish -
CPS341Z-D5 (Bulgaria)
Electrolyte for CPS341D
ElectrolytesBulgarian -
CPS341Z-D5 (Hungary)
Electrolyte for CPS341D
ElectrolytesHungarian -
CPS341Z-D5 (India)
Electrolyte for CPS341D
ElectrolytesEnglish -
CPS341Z-D5 (Czech Republic)
Electrolyte for CPS341D
ElectrolytesCzech -
CPS341Z-D5 (Denmark)
Electrolyte for CPS341D
ElectrolytesDanish -
CPS341Z-D5 (Norway)
Electrolyte for CPS341D
ElectrolytesNorwegian -
CPS341Z-D5 (Finland)
Electrolyte for CPS341D
ElectrolytesFinnish -
CPS341Z-D5 (Netherlands)
Electrolyte for CPS341D
ElectrolytesDutch -
CPS341Z-D5 (Lithuania)
Electrolyte for CPS341D
Electrolytes -
CPS341Z-D5 (Italy)
Electrolyte for CPS341D
ElectrolytesItalian -
CPS341Z-D5 (China)
Electrolyte for CPS341D
ElectrolytesChinese -
CPS341Z-D5 (Latvia)
Electrolyte for CPS341D
Electrolytes -
CPS341Z-D5 (Belgium (Dutch))
Electrolyte for CPS341D
ElectrolytesDutch -
CPS341Z-D5 (Mexico)
Electrolyte for CPS341D
ElectrolytesSpanish -
CPS341Z-D5 (Malta)
Electrolyte for CPS341D
ElectrolytesEnglish -
CPS341Z-D5 (Romania)
Electrolyte for CPS341D
ElectrolytesRomanian -
CPS341Z-D5 (Belgium)
Electrolyte for CPS341D
Electrolytesfr -
CPS341Z-D5 (Turkey)
Electrolyte for CPS341D
ElectrolytesTurkish -
CPS341Z-D5 (Poland)
Electrolyte for CPS341D
ElectrolytesPolish -
CPS341Z-D5 (Australia)
Electrolyte for CPS341D
ElectrolytesEnglish -
CPS341Z-D5 (Slovenia)
Electrolyte for CPS341D
Electrolytes -
CPS341Z-D5 (Austria)
Electrolyte for CPS341D
ElectrolytesGerman -
CPS341Z-D5 (Switzerland)
Electrolyte for CPS341D
ElectrolytesGerman -
CPS341Z-D5 (Spain)
Electrolyte for CPS341D
ElectrolytesSpanish -
CPS341Z-D5 (Portugal)
Electrolyte for CPS341D
ElectrolytesPortuguese -
CPS341Z-D5 (South Africa)
Electrolyte for CPS341D
ElectrolytesEnglish -
CPS341Z-D5 (Ukraine)
Electrolyte for CPS341D
Electrolytes -
CPS341Z-D5 (South Korea)
Electrolyte for CPS341D
Electrolytes -
CPS341Z-D5 (Sweden)
Electrolyte for CPS341D
ElectrolytesSwedish -
CPS341Z-D5 (France)
Electrolyte for CPS341D
Electrolytesfr -
CPS341Z-D5 (Japan)
Electrolyte for CPS341D
ElectrolytesJapanese -
CPS341Z-D5 (Slovakia)
Electrolyte for CPS341D
Electrolytes -
CPS341Z-D5 (Switzerland (Italian))
Electrolyte for CPS341D
ElectrolytesItalian -
CPS341Z-D5 (Estonia)
Electrolyte for CPS341D
Electrolytes -
CPS341Z-D5 (Canada (French))
Electrolyte for CPS341D
Electrolytesfr -
CPS341Z-D5 (United Arab Emirates)
Electrolyte for CPS341D
ElectrolytesEnglish -
CPS341Z-D5 (Germany)
Electrolyte for CPS341D
ElectrolytesGerman -
CPS341Z-D5 (USA)
Electrolyte for CPS341D
ElectrolytesEnglish -
CPS341Z-D5 (Russia)
Electrolyte for CPS341D
ElectrolytesRussian -
CPS341Z-D5 (New Zealand)
Electrolyte for CPS341D
ElectrolytesEnglish -
CPS341Z-D5 (Switzerland (French))
Electrolyte for CPS341D
Electrolytesfr -
CPS341Z-D5 (European Union)
Electrolyte for CPS341D
ElectrolytesEnglish -
CPS341Z-D5 (Saudi Arabien)
Electrolyte for CPS341D
Electrolytes -
CPS341Z-D5 (Canada)
Electrolyte for CPS341D
ElectrolytesEnglish -
CPS341Z-D5 (United Kingdom)
Electrolyte for CPS341D
ElectrolytesEnglish -
CPS341Z-D5 (Greece)
Electrolyte for CPS341D
ElectrolytesGreek -
CPS341Z-D5 (United Arab Emirates)
Electrolyte for CPS341D
Electrolytes -
Ceramax
Product Code: CPS341D-
Declaration Number: HE_00752_01.17
Manufacturer Specification: 1935/2004Manufacturer DeclarationGerman , English -
Ceramax
Product Code: CPS341D-
Declaration Number: FDA_00158_01.17FDA DeclarationGerman , English -
TopHit, OrbiSint, OrbiPore, Messkabel, Memosens, Memocheck, Ceramax, CeraLiquid, CeraGel
Product Code: CYP03D-, CYP02D-, CYP01D-, CYK20-, CYK10-, CPS96D-, CPS92D-, CPS91D-, CPS76D-, CPS72D-, CPS71D-, CPS491D-, CPS471D-, CPS441D-, CPS42D-, CPS41D-, CPS341D-, CPS31D-, CPS171D-, CPS16D-, CPS12D-, CPS11D-
Declaration Number: EC_00105_02.15EU DeclarationGerman , English , fr -
TopHit, Sensor, PuriSys, OrbiSint, OrbiPore, OrbiPac, Memosens, Liquisys pH/ORP, Liquisys Oxygen, Liquisys Chlorine, Liquiline M, Liquiline, CeraTex, Ceramax, CeraLiquid, CeraGel
Product Code: CPS491-, CPS47D-, CPS471D-, CPS471-, CPS441D-, CPS441-, CPS42D-, CPS42-, CPS41E-, CPS41D-, CPS41-, CPS341D-, CPS31D-, CPS31-, CPS171D-, CPS491D-, CPS64-, CPS71-, CPS71D-, CPS71E-, CPS72-, CPS72D-, CPS76D-, CPS77D-, CPS91-, CPS91D-, CPS91E-, CPS92-, CPS92D-, CPS96D-, CPS97D-, CPS16D-, CCM223-, CCM253-, CM14-, CM42-, CM442-, CM442R-, CM444-, CM444R-, CM448-, CM448R-, CM44P-, CM72-, CM82-, COM223-, COM223F-, COM253-, COM253F-, CPF201-, CPF81-, CPF81D-, CPF82-, CPF82D-, CPM223-, CPM253-, CPS11-, CPS11D-, CPS11E-, CPS12-, CPS12D-, CPS12E-, CPS13-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC RU D-DE.AD07.B.01362/19MiscellaneousRussian -
TopHit, Sensor, PuriSys, OrbiSint, OrbiPore, OrbiPac, Memosens, Liquisys pH/ORP, Liquisys Oxygen, Liquisys Chlorine, Liquiline M, Liquiline, CeraTex, Ceramax, CeraLiquid, CeraGel
Product Code: CPS47D-, CPS471D-, CPS471-, CPS441D-, CPS441-, CPS42D-, CPS42-, CPS41E-, CPS41D-, CPS41-, CPS341D-, CPS31D-, CPS31-, CPS171D-, CPS16D-, CPS491-, CPS491D-, CPS64-, CPS71-, CPS71D-, CPS71E-, CPS72-, CPS72D-, CPS76D-, CPS77D-, CPS91-, CPS91E-, CPS92-, CPS92D-, CPS96D-, CPS97D-, CCM223-, CCM253-, CM14-, CM42-, CM442-, CM442R-, CM444-, CM444R-, CM448-, CM448R-, CM44P-, CM72-, CM82-, COM223-, COM223F-, COM253-, COM253F-, CPF201-, CPF81-, CPF81D-, CPF82-, CPF82D-, CPM223-, CPM253-, CPS11-, CPS11D-, CPS11E-, CPS12-, CPS12D-, CPS12E-, CPS13-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC D-DE.AD07.B.01363/19MiscellaneousRussian -
TopHit, OxyMax W, OxyMax H, OrbiSint, OrbiPore, Messkabel, Memosens, Memocheck, ConduMax W, ConduMax H, Ceramax, CeraLiquid, CeraGel
Product Code: CYP02D-, CYP01D-, CYK20-, CYK10-, CPS96D-, CPS92D-, CPS91D-, CPS76D-, CPS72D-, CPS71D-, CPS491D-, CPS471D-, CPS441D-, CLS15D-, CLS16D-, CLS21D-, CLS82D-, COS22D-, COS51D-, CPS11D-, CPS12D-, CPS16D-, CPS171D-, CPS341D-, CPS41D-, CPS42D-
Region/Country: International (IECEx)
Approval Agency: EXAM (DMT, BVS)Explosion ProtectionEnglish -
TopHit, OxyMax W, OxyMax H, OrbiSint, OrbiPore, Memosens, ConduMax W, ConduMax H, Ceramax, CeraLiquid, CeraGel
Product Code: CPS96D-, CPS92D-, CPS91D-, CPS76D-, CPS72D-, CPS71D-, CPS491D-, CPS471D-, CPS441D-, CPS42D-, CPS41D-, CPS341D-, CPS171D-, CPS16D-, CPS12D-, CPS11D-, COS81D-, COS51D-, COS22D-, CLS82D-, CLS21D-, CLS16D-, CLS15D-
Region/Country: South Korea
Approval Agency: KTL
Protection: Ex ia IIC T6...T3Explosion Protection -
TopHit, OxyMax W, OxyMax H, OrbiSint, OrbiPore, Messkabel, Memosens, Memocheck, ConduMax W, ConduMax H, Ceramax, CeraLiquid, CeraGel
Product Code: CYP02D-, CYP01D-, CYK20-, CYK10-, CPS96D-, CPS92D-, CPS91D-, CPS76D-, CPS72D-, CPS71D-, CPS491D-, CPS471D-, CPS441D-, CPS42D-, CPS41D-, CPS341D-, CPS171D-, CPS16D-, CPS12D-, CPS11D-, COS81D-, COS51D-, COS22D-, CLS82D-, CLS21D-, CLS16D-, CLS15D-
Region/Country: International (IECEx)
Approval Agency: EXAM (DMT, BVS)Explosion ProtectionEnglish -
CeraLiquid, CeraGel, OxyMax W, OxyMax H, OrbiSint, OrbiPore, Messkabel, Memosens, Memocheck, ConduMax W, ConduMax H, Ceramax
Product Code: CYP02D-, CYP01D-, CYK20-, CYK10-, CPS92D-, CPS91D-, CPS72D-, CPS71D-, CPS491D-, CPS471D-, CPS441D-, CPS42D-, CPS41D-, CPS341D-, CPS171D-, CPS12D-, CPS11D-, COS51D-, COS22D-, COS21D-, CLS82D-, CLS21D-, CLS16D-, CLS15D-
Region/Country: Europe (ATEX)
Approval Agency: EXAM (DMT, BVS)Explosion ProtectionGerman , English -
TopHit, OxyMax W, OxyMax H, OrbiSint, OrbiPore, Messkabel, Memosens, Memocheck, ConduMax W, ConduMax H, Ceramax, CeraLiquid, CeraGel
Product Code: CYP02D-, CYP01D-, CYK20-, CYK10-, CPS96D-, CPS92D-, CPS91D-, CPS76D-, CPS72D-, CPS71D-, CPS491D-, CPS471D-, CPS441D-, CPS42D-, CLS15D-, CLS16D-, CLS21D-, CLS82D-, COS22D-, COS51D-, COS81D-, CPS11D-, CPS12D-, CPS16D-, CPS171D-, CPS31D-, CPS341D-, CPS41D-
Region/Country: International (IECEx)
Approval Agency: EXAM (DMT, BVS)Explosion ProtectionEnglish -
OxyMax W, OxyMax H, OrbiSint, OrbiPore, Messkabel, Memosens, Memocheck, ConduMax W, ConduMax H, Ceramax, CeraLiquid, CeraGel
Product Code: CYP02D-, CYP01D-, CYK20-, CYK10-, CPS92D-, CPS91D-, CPS72D-, CPS71D-, CPS491D-, CPS471D-, CPS441D-, CPS42D-, CPS41D-, CPS341D-, CPS171D-, CPS12D-, CPS11D-, COS81D-, COS51D-, COS22D-, COS21D-, CLS82D-, CLS21D-, CLS16D-, CLS15D-
Region/Country: Europe (ATEX)
Approval Agency: EXAM (DMT, BVS)Explosion ProtectionEnglish -
Turbimax, TopHit, OxyMax W, OxyMax H, OrbiSint, OrbiPore, OrbiPac, New Analyzer Platform, Memosens, InduMax P, InduMax H, ConduMax W, ConduMax H, Chloromax, Ceramax, CeraLiquid, CeraGel
Product Code: CPS171D-, CPS31D-, CPS341D-, CPS41D-, CPS41E-, CPS42D-, CPS441D-, CPS471D-, CPS47D-, CPS491D-, CPS71D-, CPS71E-, CPS72D-, CPS76D-, CPS77D-, CPS91D-, CPS91E-, CPS92D-, CPS96D-, CPS97D-, CUS50D-, CUS51D-, CUS52D-, CA80HA-, CA80SI-, CCS120D-, CCS142D-, CCS50D-, CCS51D-, CLS15D-, CLS16D-, CLS21D-, CLS50D-, CLS54D-, CLS82D-, COS22D-, COS51D-, COS61D-, COS81D-, CPF81D-, CPF82D-, CPS11D-, CPS11E-, CPS12D-, CPS12E-, CPS16D-
Region/Country: Russia
Approval Number: OC.C.31.004.A NO 75181MetrologyRussian -
Viomax, Turbimax, TopHit, OxyMax W, OxyMax H, OrbiSint, OrbiPore, OrbiPac, Memosens, Liquiline M, Liquiline, Isemax, InduMax P, InduMax H, ConduMax W, ConduMax H, Chloromax, Ceramax, CeraLiquid, CeraGel
Product Code: CPS47D-, CPS471D-, CPS441D-, CPS42D-, CPS41E-, CPS41D-, CPS341D-, CPS31D-, CPS171D-, CPS16D-, CPS12E-, CPS12D-, CPS11E-, CPS11D-, CPS491D-, CPS71D-, CPS71E-, CPS72D-, CPS76D-, CPS77D-, CPS91D-, CPS91E-, CPS92D-, CPS96D-, CPS97D-, CUS50D-, CUS51D-, CUS52D-, CAS40D-, CCS120D-, CCS142D-, CCS50D-, CCS51D-, CLS15D-, CLS15E-, CLS16D-, CLS16E-, CLS21D-, CLS21E-, CLS50D-, CLS54D-, CLS82D-, CLS82E-, CM14-, CM442-, CM442R-, CM444-, CM444R-, CM448-, CM448R-, COS22D-, COS51D-, COS61D-, COS81D-, CPF81D-, CPF82D-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: OC.C.31.004.A NO 54218/1MetrologyRussian -
Viomax, New Analyzer Platform, Memosens, InduMax P, Turbimax, TopHit, Sample Preparations, OxyMax W, OxyMax H, OrbiSint, OrbiPore, OrbiPac, OEM, ConduMax W, InduMax H, ConduMax H, Chloromax, Ceramax, CeraLiquid, CeraGel
Product Code: CPS16D-, CAS51D-, CLS50D-, COS22D-, CLS82D-, CLS54D-, CAT860-, CA80AL-, COS51D-, CPS171D-, CPS31D-, CPS341D-, CPS41D-, CPS42D-, CPS441D-, CPS471D-, CPS491D-, CPS71D-, CPS72D-, CPS76D-, CPS91D-, CPS92D-, CUS50D-, CUS52D-, CPS12D-, CPS96D-, OCCS50D-, OCUS51D-, CPS11D-, CPF82D-, CPF81D-, COS81D-, COS61D-, CLS21D-, CLS16D-, CLS15D-, CCS142D-, CAT820-, CAT810-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: DE.C.31.004.A NO 70194MetrologyRussian
Accessories / Spare parts
-
-
Order code 71118068
Kit CPS341 o-ring set DN25
-
Order code 71118070
Kit CPS341 o-ring set DN30
-
Order code 71118071
Kit CPS341D o-ring set different types
-
Order code 71118072
Kit CPS341D gasket clamp DIN, DN100
-
Order code 71118073
Kit CPS341D insertadapt.reservoir compl.
-
Order code 71118074
Kit CPS341D needle with holder complete
-
Order code 71118075
Kit CPS341D connect electr. reservoir
-
Order code 71300741
Kit CPS341D: KCl connection sensor
-
Order code 71300743
Kit CPS341D: Hose coupling electrolyte
-
Order code 71300744
Kit CPS341D: Hose connection KCl vessel
-
Order code 71300746
Kit CPS341D: Needle electrolyte vessel
-
Order code 71330336
Kit CPS341D Tap DN25 adapter
-
Order code 71330337
Kit CPS341D Tap DN30 adapter
-
Order code 71330338
Kit CPS341D Varivent DN50 adapter
-
Order code 71330339
Kit CPS341D Dairy fitting DN50 adapter
-
Order code 71330340
Kit CPS341D Dairy fitting DN25 adapter
-
Order code 71330341
Kit CPS341D Tri-clamp DN50 adapter
-
Order code CPS341Z-
accessory for Ceramax CPS341D
-