Conductivity compact device
Smartec CLD134
Toroidal conductivity measuring system for hygienic and sterile applications
Smartec CLD134 is a measuring system for inductive conductivity in the food & beverage and life sciences industries. The combination of a transmitter and a sensor is interference-free and especially easy-to-use. It meets the highest hygienic and sterile demands thanks to its food-grade virgin PEEK body, its jointless and creviceless design and its hygienic certificates. Smartec CLD134 is therefore the ideal package to ensure the highest safety and quality of your products and processes.
-
Benefits
Unique hygienic design avoids recontamination
With all hygienic certificates required in hygienic and sterile applications
Certified biocompatibility according to USP class VI
Compliant with EG 2023/2006 and 1935/2004
-
Suitable for cleaning-in-place (CIP)...
-
Field of application
The hygienic Smartec CLD134 measures toroidal conductivity in food & beverage and life science applications:
Phase separation of product/water and product/product mixtures in pipe systems
Control of CIP processes in the return channel
Concentration...
Documents / Manuals / Software
-
Smartec CLD134
Technical Information
Hygienic measuring system
Technical Information (TI) -
Smartec CLD18
Conductivity measuring system
Operating Instruction (BA) -
Smartec CLD134
Operating Instructions
Conductivity measuring system
Operating Instruction (BA) -
Operating Instructions Smartec CLD132/134
PROFIBUS PA/DP
Operating Instruction (BA) -
Brief Operating Instructions
Smartec S CLD134
Conductivity Measuring System
Short Instruction (KA)07/07English -
Manufacturer Declaration
TSE/BSE free
Certificate (ZE) -
EHEDG certificate
EHEDG certificate of compliance
Special Documentation (SD) -
Измерение электропроводимости и концентрации
Приборы промышленного анализа жидкости для измерения
проводимости и концентрации водных растворов.
Обзорная брошюра.Fields of Activities (FA)03/05Russian -
Cleaning in Place (CIP)
Portfolio of Endress+Hauser solutions
Competence Brochure (CP)05/15English -
Cleaning in Place (CIP)
Portfolio of Endress+Hauser solutions
Competence Brochure (CP)02/18English -
GSD Single, GSD_EH_DP_AN_Smartec_0x153D_V01_50_DPLIB, 14.04.2014 (Analysi
s, Smartec S, 0x153D)
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.50.00Language neutral -
GSD Single, GSD_EH_PA_AN_SmartecS_0x151B_0x01_0x01, 11.11.2016 (Analysis,
Smartec S, 0x151B)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_EH_PA_AN_SmartecS_0x153E_0x01_0x01, 11.11.2016 (Analysis,
Smartec S, 0x153E)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_EH_DP_AN_SmartecS_0x151A_0x01_0x01, 11.11.2016 (Analysis,
Smartec S, 0x151A)
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDD Single, PDM_PA_AN_SmartecS_0x153E_0x03_0x02, 07.01.2019 (Analysis, Smartec, 0x153E)
PROFIBUS PA,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_AN_SmartecS_0x151B_0x01_0x01, 07.01.2019 (Analysis, Smartec, 0x151B)
PROFIBUS PA,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, SmartecSDP_CLD132_V1_50, 13.07.2019 (Analysis, Smartec, 0x153D)
PROFIBUS DP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, SmartecS_CLD132_V1_50, 13.07.2019 (Analysis, Smartec, 0x153E)
PROFIBUS PA,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, SmartecS_CLD132_V1_11, 13.07.2019 (Analysis, Smartec, 0x0097)
HART,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.4.188.39Language neutral -
Measurement of electrical conductivity
(.mp4 format, 116 MB)
The conductivity of a liquid can be measured using the conductive or
toroidal measuring principles. This video shows what it is about and how
these measuring principles work.Animation01/14Polish -
Measurement of electrical conductivity
(.mp4 format, 70,7MB)
The conductivity of a liquid can be measured using the conductive or
toroidal measuring principles. This video shows what it is about and how
these measuring principles work.Animation01/14fr -
InduMax H, SmarTec, SmarTec S
Product Code: CLD134-, CLD18-, CLS54-, CLS54D-
Declaration Number: HE_00726_03.17
Manufacturer Specification: 1935/2004Manufacturer DeclarationGerman , English -
InduMax H, SmarTec, SmarTec S
Product Code: CLD134-, CLD18-, CLS54-, CLS54D-
Declaration Number: HE_00726_01.17
Manufacturer Specification: 1935/2004Manufacturer DeclarationGerman , English -
InduMax H, SmarTec S
Product Code: CLD134-, CLS54-, CLS54D-
Declaration Number: HE_01099_01.19Manufacturer DeclarationEnglish -
SmarTec S
Product Code: CLD134-
Declaration Number: HE_01130_01.19
Manufacturer Specification: 10/2011, 1935/2004Manufacturer DeclarationGerman , English -
SmarTec S
Product Code: CLD134-
Declaration Number: FDA_00162_01.17FDA DeclarationGerman , English -
SmarTec S
Product Code: CLD134-
Declaration Number: EC_00371_02.16EU DeclarationGerman , English , fr -
SmarTec S, SmarTec, Sensor, Memosens, Liquisys Conductivity, Liquiline, InduMax P, InduMax H, ConduMax W, ConduMax H, Chloromax, ANALOG
Product Code: CLM253-, CLS12-, CLS13-, CLS15-, CLS15D-, CLS16-, CLS16D-, CLS19-, CLS21-, CLS21D-, CLS30-, CLS50-, CLS50D-, CLS54-, CLS54D-, CLS82D-, CYM290-, CLM223F-, CLM223-, CLD18-, CLD134-, CLD132-, CCS55D-, CCS51D-, CCS51-, CCS50D-, CCS50-, CCS241-, CCS240-, CCS142D-, CCS141-, CCS140-, CCS120D-, CCS120-
Region/Country: Russia (Declaration of Conformity)
Approval Number: EAEC RU D-DE.AD07.B.01363/19MiscellaneousRussian -
ConduMax H, ConduMax W, InduMax H, InduMax P, Liquisys Conductivity, Memosens, SmarTec, SmarTec S
Product Code: CLS82D-, CLS54D-, CLS54-, CLS50D-, CLS50-, CLS30-, CLS21D-, CLS21-, CLS19-, CLS16D-, CLS16-, CLS15D-, CLS15-, CLS13-, CLS12-, CLM253-, CLM223F-, CLM223-, CLD18-, CLD134-, CLD132-
Approval Number: EAEC RU D-DE.AD.07.B.01362/19MiscellaneousRussian -
InduMax H, Memosens, SmarTec, SmarTec S, TopHit, UniFit H
Product Code: CPS77D-, CPS47D-, CPS471D-, CPS471-, CPS441D-, CPS441-, CPA842-, CLS82D-, CLS54D-, CLS54-, CLD18-, CLD134-
Region/Country: USA
Approval Agency: 3-A Sanitary StandardsHygienic EquipmentEnglish -
InduMax H, Memosens, SmarTec, SmarTec S, TopHit, UniFit H
Product Code: CLD134-, CLD18-, CLS54-, CLS54D-, CLS82D-, CPA442-, CPS441-, CPS441D-, CPS471-, CPS471D-, CPS47D-, CPS77D-
Region/Country: USA
Approval Agency: 3-A Sanitary StandardsHygienic EquipmentEnglish -
InduMax H, Memosens, SmarTec, SmarTec S, TopHit, UniFit H
Product Code: CLD134-, CLD18-, CLS54-, CLS54D-, CLS82D-, CPA442-, CPS441-, CPS441D-, CPS471-, CPS471D-, CPS47D-, CPS77D-
Region/Country: USA
Approval Agency: 3-A Sanitary StandardsHygienic EquipmentEnglish -
InduMax H, SmarTec S
Product Code: CLD134-, CLS54-, CLS54D-
Region/Country: Canada (CRN)
Approval Agency: CRNPressure EquipmentEnglish -
InduMax H, SmarTec S
Product Code: CLD134-, CLS54-, CLS54D-
Region/Country: Canada (CRN)
Approval Agency: CRNPressure EquipmentEnglish -
ConduMax H, ConduMax W, InduMax H, InduMax P, Liquisys Conductivity, SmarTec S
Product Code: CLS54-, CLS52-, CLS50-, CLS30-, CLS21-, CLS19-, CLS16-, CLS15-, CLS13-, CLS12-, CLM253-, CLM223-, CLD134-, CLD132-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: DE.C.31.004.A_66843MetrologyRussian -
Liquisys Chlorine, Liquisys Conductivity, LIQUISYS M, Liquisys Oxygen, Liquisys Turbidity, SmarTec S
Product Code: CUM253-, CUM223-, CPM253-, CPM223-, COM253F-, COM253-, COM223F-, COM223-, CLM253-, CLM223F-, CLM223-, CLD134-, CCM253-, CCM223-
Region/Country: Canada, USA
Approval Agency: CSAOrdinary Location Product SafetyEnglish -
UniFit H, TopHit, SmarTec S, SmarTec, ProbFit H, Memosens, InduMax H, CleanFit H
Product Code: CLS54D-, CLS82D-, CPA442-, CPS441-, CPS441D-, CPS471-, CPS471D-, CLD134-, CLD18-, CLS54-
Region/Country: USA
Approval Agency: 3-A Sanitary StandardsFood SafetyEnglish
Accessories / Spare parts
-
-
Order code
Please order a standard sensor CLS54 for non- compact version
-
Order code 71020487
Kit CLD134, version MV5, spare sensor
-
Order code 71020488
Kit CLD134, version AA5, spare sensor
-
Order code 71020489
Kit CLD134, version CS1, Spare sensor
-
Order code 71020490
Kit CLD134, version SMS, spare sensor
-
Order code 71020491
Kit CLD134, version VA4, spare part
-
Order code 71020492
Kit CLD134, version BC5, spare sensor
-
Order code 71020493
Kit CLD134 version AA5, sensor USP 87
-
Order code 71020495
Kit CLD134 version CS1, sensor USP 87
-
Order code 71020496
Kit CLD134 version VA4, sensor USP 87
-
Order code 71020497
Kit CLD134 version BC5, sensor USP 87
-
Order code 71025965
Kit CLD134 Main module 1 output
-
Order code 71025968
Kit CLD134 Main module 2 outputs
-
Order code 71025969
Kit CLD134 Main module 1 output + HART
-
Order code 71025970
Kit CLD134 Main module 2 outputs+HART
-
Order code 71025971
Kit CLD134 Main module Profibus PA
-
Order code 71025972
Kit CLD134 main module Profibus DP
-
Order code 71134734
Kit CLD134: Central mod. PB DP; H/W 2.1x
Content: 1x Central module Profibus DP Module name: LSCP-DP qualified from H/W 2.10
-
Order code 71134735
Kit CLD13x: Terminal module for PB DP
Content: 1x Terminal module Profibus DP Module name : LSKB qualified for central mod. from H/W 2.10
-
Order code 71161133
Kit: MKIC Conductiv. transmitter Non-Ex
-
Order code 51501585
Kit CLD132/4 Power supply 100/115/230VAC
-
Order code 51501586
Kit CLD132/4 Power supply 24 V AC/DC
-
Order code 51501574
Kit CLD132/4 lower casing seperate vers.
-
Order code 51501576
Kit CLD132/4 lower casing compact vers.
-
Order code 50062121
Round post installation for CYY101
-
Order code 51501577
Kit CLD132/4 housing cover complete
-
Order code 51501584
Kit CLD132/4 module box
-
Order code 51502280
Kit CLD132/4 module box for PA/DP
-
Order code 51501587
Kit CLD132/4 Terminal blocks 5+8+13 pol.
-
Order code 51502281
Kit CLD132/4 Terminal block set PA/DP
-
Order code 51501588
Kit CLD132/4 Flat ribbon cable 20 poles
-
Order code 51502282
Kit CLD132/4 M20 glands+Goretex filter
-
Order code 51502283
Kit CLD132/4 Contuit glands+Goretex
-
Order code 51501596
Kit CLD132/4 Sealings and small parts
-
Order code 51502382
Kit CLD132/4 Protection against contact
-
Order code 51501643
Upgrade"Extended Functions"for Smartec
-
-
Predecessor