Specs at a glance
-
Accuracy
Standard acc. to ASTM E-230
Special acc. to ASTM E-230 -
Response time
63% rt = 0.3 s
-
Max. process pressure (static)
at 20°C: 250 bar (3.626 psi)
depends on configuration -
Operating temperature range
Type T:
-270 °C ...400 °C
(-454 °F ...752 °F)
Type J:
-210 °C ...1.200 °C
(-346 °F ...2.192 °F)
Type E:
-270 °C ...1.000 °C
(-454 °F ...1.832 °F)
Type K:
-270 °C ...1.372 °C
(-454 °F ...2.500 °F)
Type N:
-270 °C ... 1.300 °C
(-454 °F ...2.372 °F) -
Max. immersion length on request
up to 96" (2.438 mm)
others on request
Field of application
The high modular thermometer is used for several applications in almost all industries. Examples are heat exchangers, furnaces, dryers, process reactors, etc. With different head transmitter it's a complete unit ready for use with enhanced measurement accuracy and reliability. It also enables very fast response times, due to direct contact measurement without thermowell. A variety of process connections and dimensions offer flexible application possibilities.
Magnesium oxide insulated thermocouples, commonly referred to as MgO thermocouples, are used in many process and laboratory applications. They have many desirable characteristics making thermocouples a good choice for general and special purpose applications.
The sensors can be used on:
Heat exchangers
Power & recovery areas
Furnaces
Dryers
Flue gas
Compressor stations
Process reactors
Metallurgical and glass manufacturing
Benefits
One source shopping for temperature measurement solutions. World class transmitter with integrated sensor offering. Remove and install straight out of the box!
Improved galvanic isolation on most devices (2 kV)
Simplified model structure: Competitively priced, offers great value. Easy to order and reorder. A single model number includes sensor and transmitter assembly for a
complete point solution.All iTEMP® transmitters provide long term stability ≤ 0.05 % per year
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
| FLEX selections | Technical excellence | Simplicity |
|---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Measuring principle
Thermocouple
-
Characteristic / Application
US style
modular temperature assembly
threaded process connection -
Thermowell / protection tube
without (not intended to use with thermowell)
-
Insert / probe
mineral insulated (MI), flexible
-
Outer diameter protection tube / Insert
1/8'' (3,18 mm)
3/16''(4,76 mm)
1/4'' (6,35 mm)
3/8'' (9,53 mm) -
Max. immersion length on request
up to 96" (2.438 mm)
others on request -
Material protection tube/ thermowell
316
Alloy 600 -
Optional coating
Not applicable
-
Process connection
male thread:
G1/2"
NPT1/2"
compression fitting:
NPT1/8"
NPT1/4" -
Tip shape
straight
-
Surface roughness Ra
Not defined
-
Operating temperature range
Type T:
-270 °C ...400 °C
(-454 °F ...752 °F)
Type J:
-210 °C ...1.200 °C
(-346 °F ...2.192 °F)
Type E:
-270 °C ...1.000 °C
(-454 °F ...1.832 °F)
Type K:
-270 °C ...1.372 °C
(-454 °F ...2.500 °F)
Type N:
-270 °C ... 1.300 °C
(-454 °F ...2.372 °F) -
Max. process pressure (static)
at 20°C: 250 bar (3.626 psi)
depends on configuration -
Accuracy
Standard acc. to ASTM E-230
Special acc. to ASTM E-230 -
Response time
63% rt = 0.3 s
-
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Ex - approvals
transmitter only
FM IS
CSA IS
FM/CSA IS -
Certification
SIL (transmitter only)
-
-
Technical Information (TI)
TI TH51, TH52 and TH56
-
Technical Information (TI)
English version - 01/2025New version available in EnglishGeneral purpose MgO insulated thermocouples with connection head, extension lead wires or connectors for process and laboratory appl
icationsEN 15/01/202515/02/202314/01/202131/05/201826/06/2015Language:
English
Version:
15/01/2025
File size:
1.5 MB
File name:
TI00111REN_1725-00.pdf
-
-
-
Short Instruction (KA)
TH51 Compact Instructions
-
Short Instruction (KA)
English version - 02/2013New version available in EnglishThermocouple assembly
EN 04/02/201301/07/200501/10/2004Language:
English
Version:
04/02/2013
File size:
569.8 KB
File name:
KA00184ren_1312.pdf
-
-
-
Special Documentation (SD)
Device viewer
-
Special Documentation (SD)
English version - 07/2021New version available in EnglishTechnical documentation in other languages
Language:
English
Version:
14/07/2021
File size:
478.5 KB
File name:
SD02429R09EN_0121.pdf
-
-
-
Fields of Activities (FA)
Temperaturmesstechnik
-
Fields of Activities (FA)
German version - 02/2025New version available in EnglishThermometer und Transmitter für die Prozessindustrie
Language:
German
Version:
04/02/2025
File size:
18.9 MB
File name:
FA00006Tde_2325.pdf
-
-
-
Fields of Activities (FA)
Temperature measurement
-
Fields of Activities (FA)
English version - 02/2025New version available in EnglishThermometers and transmitters for the process industry
Language:
English
Version:
04/02/2025
File size:
18.8 MB
File name:
FA00006Ten_2325_interaktiv_verb.pdf
-
-
-
Fields of Activities (FA)
Misura della temperatura
-
Fields of Activities (FA)
Italian version - 07/2024New version available in EnglishMisura della temperatura
Termometri e trasmettitori per l'industria di processoLanguage:
Italian
Version:
09/07/2024
File size:
20.3 MB
File name:
FA00006Tit_2223.pdf
-
-
-
Fields of Activities (FA)
Misura della temperatura
-
Fields of Activities (FA)
Italian version - 02/2020New version available in EnglishTermometri e trasmettitori per l'industria di processo
Language:
Italian
Version:
17/02/2020
File size:
30.6 MB
File name:
FA00006TIT_2020.pdf
-
-
-
Fields of Activities (FA)
Mesure de température
-
Fields of Activities (FA)
French version - 12/2019New version available in EnglishCapteurs et transmetteurs de température pour les industries de process
Language:
French
Version:
20/12/2019
File size:
60.9 MB
File name:
FA00006TFR-Mesure de temperature.pdf
-
-
-
Fields of Activities (FA)
Catálogo medición temperatura
-
Fields of Activities (FA)
Spanish version - 04/2018New version available in EnglishTermómetros y transmisores para la industria de proceso
Language:
Spanish
Version:
20/04/2018
File size:
5.5 MB
File name:
FA00006Tes_Catalogo Temperatura_1818.pdf
-
-
-
Fields of Activities (FA)
温度計
-
Fields of Activities (FA)
Japanese version - 02/2020New version available in Englishプロセス産業向けの温度計
および伝送器Language:
Japanese
Version:
17/02/2020
File size:
47 MB
File name:
FA00006TJA_2020.pdf
-
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD drawings CAD drawings
- CAD drawings
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons
Individual configuration
Often bought together
Accessories
Related products