Mycom S CLM153
This product is no longer available.
Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.
Documents / Manuals / Software
-
Technical Information MYPRO CL
Two-wire transmitter for inductive measurement of conductivity in Ex and
non-Ex areas with HART® or PROFIBUS communicationTechnical Information (TI) -
Technical Information Mycom S CLM153
Conductivity transmitter
Technical Information (TI) -
Operating Instructions Mycom S CLM153
Conductivity Transmitter
Operating Instruction (BA) -
Operating Instructions Mycom S CXM 153 PROFIBUS
Field Communication with
Mycom S CXM 153
TopCal S CPC 300
TopClean S CPC 30Operating Instruction (BA) -
Operating Instructions Mycom S CXM 153 HART
Field Communication with
Mycom S CXM 153
TopCal S CPC 300
TopClean S CPC 30Operating Instruction (BA) -
Safety Instruction Mycom S CXM153-O/-P
Safety instructions for electrical equipment in hazardous areas, FM
approvedEx Safety Instructions (XA) -
Ex Safety Instructions Mycom S CXM153-G
Sicherheitshinweise für explosionsgefährdete Bereiche.
Safety instructions for hazardous areas.
Conseils de sécurité pour zones explosibles.Ex Safety Instructions (XA) -
Safety Instructions CSA CXM153
Transmitter
Ex Safety Instructions (XA) -
Измерение электропроводимости и концентрации
Приборы промышленного анализа жидкости для измерения
проводимости и концентрации водных растворов.
Обзорная брошюра.Fields of Activities (FA)03/05Russian -
One for all - The new generation of conductivity transmitters by Endress+Hauser
Process control through conductivity measurement is widely found in todays process industry. As similar the available measuring
principles are as different are the applications: From pure water production for the pharmaceutical industry to concentration
controlof acids and caustic it provides a reliable measuring point with little service requirements.
In many cases conductivity
loops inone plant have different task and thus have to be equipped with instruments of different models or even different
suppliers. With the introduction of the new Mycom S CLM153 Endress+Hauser offers one instrument for all common conductivity
applications that allows standardization for the user. Together with a wide selection of conductivity sensors complete solutions
are offered to the customer.Special Promotion (SP)English -
GSD Single, GSD_EH_PA_AN_Mycom_0x1535_V01_20_PALIB, 22.04.2014 (Analysis,
Mycom S, 0x1535)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.20.00Language neutral -
GSD Single, GSD_EH_PA_AN_Mycom_0x1537_V01_20_PALIB, 22.04.2014 (Analysis,
Mycom S, 0x1537)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.20.00Language neutral -
EDD Single, PDM_PA_AN_MycomS_0x1537_0x02_0x02, 07.01.2019 (Analysis, Mycom S, 0x1537)
PROFIBUS PA,
PDM Version: 5.2 SP1, 6.0 SP5, 6.1, 8.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_AN_MycomS_0x1535_0x01_na, 19.05.2015 (Analysis, Mycom
S)
PROFIBUS PA,
PDM Version: 6.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_AN_MycomS_0x1535_0x02_0x02, 07.01.2019 (Analysis, Mycom S, 0x1535)
PROFIBUS PA,
PDM Version: 5.2 SP1, 6.0 SP5, 6.1, 8.1Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, MycomS_CLM153cond_PA_V1_20, 10.07.2019 (Analysis, Mycom S, 0x1535)
PROFIBUS PA,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, MycomS_CLM153ind_PA_V1_20, 10.07.2019 (Analysis, Mycom S, 0x1537)
PROFIBUS PA,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, MycomSCond_I_CLM153_V1_20, 10.07.2019 (Analysis, Mycom S, 0x009A)
HART,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, MycomSCond_C_CLM153_V1_20, 10.07.2019 (Analysis, Mycom S, 0x0099)
HART,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.4.188.39Language neutral -
Measurement of electrical conductivity
(.mp4 format, 70,7MB)
The conductivity of a liquid can be measured using the conductive or
toroidal measuring principles. This video shows what it is about and how
these measuring principles work.Animation01/14fr -
Measurement of electrical conductivity
(.mp4 format, 116 MB)
The conductivity of a liquid can be measured using the conductive or
toroidal measuring principles. This video shows what it is about and how
these measuring principles work.Animation01/14Polish -
TOCII, Stip-Scan, Stamolys, Sensor, Mycom S, Liquisys pH/ORP, Liquisys Oxygen, Liquisys Conductivity, Liquisys Chlorine, Liquiline M, Liquiline
Product Code: CPM253-, CPM223-, CPM153-, COM253-, COM223-, CM448-, CM444-, CM442-, CM14-, CLM253-, CLM223-, CLM153-, CCM253-, CCM223-, CAM74-, CA72TOC-, CA71SI-, CA71PH-, CA71NO-, CA71MN-, CA71HY-, CA71HA-, CA71FE-, CA71CU-, CA71CR-, CA71COD-, CA71CL-, CA71AM-, CA71AL-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC № RU D-DE.MU62.B.02737MiscellaneousRussian -
Mycom S
Product Code: CLM153-, CPM153-
Region/Country: Europe (ATEX)
Approval Agency: DMT
Category: II (1) 2G
Protection: EEx em [ia/ib] IIC T4Explosion ProtectionEnglish -
Mycom S
Product Code: CPM153-, CLM153-
Region/Country: USA
Approval Agency: FM
Category: I, 2, ABCD, II, III, 1, EFG
Protection: DIP, IS, NEMA4X, NIExplosion ProtectionEnglish -
Mycom S
Product Code: CLM153-, CPM153-
Region/Country: Canada, USA
Approval Agency: CSA
Protection: Type 4, Cl. I, Div.2 Grp.A,B,C,D, Cl. II, Div.1,, Cl. I, Div.2 Grp.A,B,C,D, Cl.Explosion ProtectionEnglish -
Mycom S
Product Code: CLM153-, CPM153-
Region/Country: Europe (ATEX)
Approval Agency: DMT
Category: II (1) 2G
Protection: EEx em [ia/ib] IIC T4Explosion ProtectionGerman , English -
Mycom S
Product Code: CLM153-, CPM153-
Region/Country: Europe (ATEX)
Approval Agency: DMT
Category: II (1) 2G
Protection: EEx em [ia/ib] IIC T4Explosion ProtectionGerman , English -
TopHit, TopClean S, TopCal S, ConduMax W, InduMax P, Single electrode, Sensor, ConduMax H, CeraGel, OrbiSint, OrbiPore, CeraLiquid, Mycom S
Product Code: SPC441D-, CPS91-, CPS71-, CPS64-, CPS491D-, CPS471D-, CPS42-, CPS41D-, CPS41-, CPS13-, CPS12-, CPS11-, CPM153-, CPC310-, CPC30-, CLS50D-, CLS50-, CLS21D-, CLS21-, CLS16D-, CLS16-, CLS15D-, CLS15-, CLS13-, CLS12-, CLM153-
Region/Country: Russia
Approval Agency: EACExplosion ProtectionRussian -
Mycom S
Product Code: CLM153-, CPM153-
Region/Country: Europe (ATEX)
Approval Agency: DMT
Category: II (1) 2G
Protection: EEx em [ia/ib] IIC T4Explosion ProtectionEnglish
Accessories / Spare parts
-
-
Order code 51517392
KIT CLM153 cond: contr. 2xI +HART/non Ex
-
Order code 51517390
KIT CLM153 cond: contr. mod. 2xI /nonEx
-
Order code 51517394
KIT CLM153 cond: contr. PA / non-Ex
-
Order code 51517398
KIT CLM153 ind. contr. 2x I+HART/nonEx
-
Order code 51517396
KIT CLM153 ind. contr. 2x I, non Ex
-
Order code 51517400
KIT CLM153 ind. controller PA / non-Ex
-
Order code 51507101
KIT CLM153 sensor terminals 6+2 poles
-
Order code 51507091
KIT CXM153 DC/DC converter for input 2
-
Order code 71003923
KIT CXM153 Enclosure top complete non-Ex
-
Order code 51507106
KIT CXM153 Enclosure bottom 1/2ch non-Ex
-
Order code 51507084
KIT CXM153 terminal module non Ex
-
Order code 51510998
KIT CXM153 terminal mod. PA / non-Ex
-
Order code 51507087
KIT CXM153 powersupply 100-230VAC non-Ex
-
Order code 51507089
KIT CXM153 power supply 24 VAC/DC non-Ex
-
Order code 51507099
KIT CXM153 relay mod. 1 rel.+ 2 input I
-
Order code 51509513
KIT CXM153 relay mod. 1xrel+1xIin+1xRin
-
Order code 51507098
KIT CXM153 relay mod. 2 rel.+ 1 inp. I
-
Order code 51509510
KIT CXM153 relay mod. 2xrel.+ 1xinput R
-
Order code 51507097
KIT CXM153 relay module 3 relay
-
Order code 51507103
KIT CXM153 Partition wall (5 pcs.)
-
Order code 51507102
KIT CXM153 Jumper set (5 complete sets)
-
Order code 71161133
Kit: MKIC Conductiv. transmitter Non-Ex
-
Order code 51511383
Mounting set for housing CxM152/153
-
Order code 51507175
DAT module
Memorymodule for copying a transmitter setup. Also for setup with ParaWin.
-
-
Predecessor
-
Successor