Specs at a glance
-
Process temperature
-50 °C...+150 °C
(-58 °F...+302 °F) -
Process pressure absolute / max. overpressure limit
Vacuum...64 bar
(Vacuum...928 psi) -
Min. density of medium
0.5g/cm³ (0.4g/cm³ optional)
Field of application
Liquiphant FTL51H is a point level switch with extension tube for use in hazardous areas with all international certificates. Especially useable in the food and life sciences industry with hygienic certificates (3-A, EHEDG, ASME BPE). FTL51H offers functional safety SIL2/SIL3. Reliable measurement values, not affected by: changing media properties, flow, turbulences, gas bubbles, foam, vibrations or build-up.
Point level switch for all liquids with electro-polished surface finishing.
Process connections: Threads, flanges and hygienic process connection (Tri-Clamp, dairy coupling, aseptic, DRD, SMS, Varivent)
Temperature: -50 to +150°C (-58 to +302°F)
Pressure: -1 to +64bar (-14.5 to +928psi)
Sensor material: 316L
International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approvals
Benefits
International hygienic certificates (3-A, EHEDG, ASME BPE). FDA-conformed material
Electro-polished and passivated surface finishing
International explosion protection certificates and overfill prevention certificate (WHG)
No mechanically moving parts: no maintenance, no wear, long operating life.
Monitoring of fork for damage: guaranteed functionUse in safety systems requiring functional safety to SIL2/SIL3 in accordance with
IEC 61508/IEC 61511-1No calibration required, easy to start up
Variety of standardized hygienic process connections for hygiene sensitive applications
Videos
-
Vibronic measuring principle
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
Measuring principle
Vibration Density
-
Characteristic / Application
Liquiphant M Density
with Density Computer FML621
Temperature and pressure measurement
Modular & completely welded housing concept
Focus Food & Pharma
Surface up to 0.3 µ
Variable sensor length up to 3 m (6 m option) -
Supply / Communication
Transmitter power supply (MUS)
-
Ambient temperature
-50...70°C
-50...60°C for hazardous applications -
Process temperature
0...80°C (validity of accuracy data)
-50...0°C / 80...150°C (with reduced technical data) -
Process pressure absolute
0...25 bar
>25...64 bar (with reduced technical data) -
Wetted parts
316L
-
Hygienic
3A
EHEDG -
Sensor length
115...3000 mm
>3000...6000 mm (Option) -
Output
Pulse
-
Certificates / Approvals
ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI
-
Specialities
Commissioning with ReadWin2000
-
Components
Density Computer FML621
-
Other approvals and certificates
SIL2/ SIL3
-
Measuring principle
Vibration Liquids
-
Characteristic / Application
Modular & completely welded housing concept
Focus Food & Pharma
surface up to 0,38µm electro polished
wide range of process connections
Analogue and bus interfaces
Extensive certificate range (e.g. EHEDG,3A)
Compact, e.g. pipes
variable sensor length up to 3m (6m option) -
Specialities
Foamdetection
Detect changes of the density -
Supply / Communication
PROFIBUS PA
19...253V AC
10...55V DC-PNP
19...253V AC bzw 10...55V DC
8/16mA, 11...36V DC
NAMUR
PFM -
Ambient temperature
-50 °C...+70 °C
(-58 °F...+158 °F) -
Process temperature
-50 °C...+150 °C
(-58 °F...+302 °F) -
Process pressure absolute / max. overpressure limit
Vacuum...64 bar
(Vacuum...928 psi) -
Min. density of medium
0.5g/cm³ (0.4g/cm³ optional)
-
Main wetted parts
316L
-
Process connection
Thread:
G3/4A, G1A, R3/4", R1, NPT3/4, NPT1
Flange:
DN25...DN100,
ASME 1"...4",
JIS 25A...100A -
Process connection hygienic
Tri-Clamp ISO2852
Dairy coupling
Aseptic
DRD
SMS
Varivent -
Sensor length
Length 130mm (5.12") (Liquiphant II)
148mm...6000mm (5.83...236") -
Communication
PROFIBUS PA
19...253V AC
10...55V DC-PNP
19...253V AC bzw 10...55V DC
8/16mA, 11...36V DC
NAMUR
PFM -
Certificates / Approvals
ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI
-
Safety approvals
SIL2/ SIL3
-
Design approvals
EN 10204-3.1
AD2000 -
Hygienic approvals
CoC ASME-BPE
-
Marine approval
GL/ ABS/ DNV
-
Components
FTL325P/FTL375P Interface PFM
FTL325N/FTL375N Interface NAMUR
Configure to download the CAD drawings of this product
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons
Individual configuration
Often bought together
Accessories
Related products