Differential pressure
Deltabar FMD78
Differential pressure transmitter with two diaphragm seals for differential pressure and level
The Deltabar FMD78 differential pressure transmitter with metal sensor uses two capillary diaphragm seals. Typically used in process and hygiene applications for continuous measurement of pressure differences in liquids, vapors, gases and dusts. The integrated HistoROM data module makes the management of process and device parameters easy. Designed according to IEC 61508 for use in SIL3 safety applications.
-
Benefits
Large variety of different process connections and membrane materials
New TempC Membrane for diaphragm seals: Minimum temperature effects and short recovery times
Highest safety due to gas tight feedthrough with capabilities up to SIL2/3, certified to IEC...
-
Field of application
For differential pressure, level, volume or mass measurement in liquids.
Process connections: Threads, flanges, pancake and hygienic connections
Process temperature: -70 up to +400°C (-94 to +752°F)
Measuring ranges: 100mbar to +40 bar (1.5 to 600psi)
...
Documents / Manuals / Software
-
Deltabar S
PMD75, FMD77, FMD78
Technical Information
Differential pressure transmitter, used for measuring flow rate, level,
pressure and differential pressure.Technical Information (TI) -
Weld-in adapter, process adapter and flanges
Level and pressure measurement
Technical Information (TI) -
Deltabar S FMD77, FMD78, PMD75
HART V02.30.zz
Operating Instructions
Differential pressure transmitter with metal sensors
Operating Instruction (BA) -
Deltabar S FMD77/78; PMD75
PROFIBUS PA (V 04.01.zz)
Operating Instructions
Differential pressure transmitter with ceramic and silicon sensors
Overload-resistant and function-monitored
Communication via
PROFIBUS PAOperating Instruction (BA) -
Cerabar S /Deltabar S /Deltapilot S
Description of device
functions
PROFIBUS PA
V04.01.zz
Cerabar S PMC71, PMP71, PMP75 Pressure transmitter
Deltabar S FMD77, FMD78, PMD75 Differential pressure
transmitter
Deltapilot S FMB70 Hydrostatic pressure transmitterOperating Instruction (BA) -
Cerabar S / Deltabar S / Deltapilot S
HART V02.30.zz
Description of Instrument Functions
Cerabar S PMC71, PMP71, PMP75 Pressure transmitter
Deltabar S FMD77, FMD78, PMD75 Differential pressure transmitter
Deltapilot S FMB70 Hydrostatic pressure transmitterOperating Instruction (BA) -
Cerabar S / Deltabar S / Deltapilot S, Description of device functions
FOUNDATION Fieldbus
V 04.00.zz
Cerabar S PMC71, PMP71, PMP75 Pressure transmitter
Deltabar S FMD77, FMD78, PMD75 Differential pressure
transmitter
Deltapilot S FMB70 Hydrostatic pressure transmitterOperating Instruction (BA) -
Deltabar S FMD77/78; PMD75
FOUNDATION Fieldbus (V 04.00.zz)
Operating Instructions
Differential pressure transmitter with ceramic and silicon sensors
Overload-resistant and function-monitored
Communicationvia
FOUNDATION FieldbusOperating Instruction (BA) -
Cerabar S, Deltabar S, Deltapilot S
Cerabar S, Deltabar S, Deltapilot S
Process pressure measurement/differntial pressure
measurement/hydrostatic level measurement
V 04.00.zzShort Instruction (KA)12/14German , English -
Cerabar S, Deltabar S, Deltapilot S
Cearabar S - pressure transmitter
Deltabar S - differential
pressure transmitter
Deltapilot S - hydrostatic transmitterShort Instruction (KA)12/14German , English -
Deltabar S FMD77/78; PMD75
Brief Operating Instructions
Differential pressure transmitter with ceramic and silicon sensors
Overload-resistant and function-monitored
Communicationvia
FOUNDATION FieldbusShort Instruction (KA)04/17English -
Deltabar S FMD77/78; PMD75
Brief Operating Instructions
Differential pressure transmitter with ceramic and silicon sensors
Overload-resistant and function-monitored
Communicationvia
PROFIBUS PAShort Instruction (KA)04/17English -
Exchange of electronics on Cerabar S, Deltabar S, and Deltapilot S
Austausch der Elektronik am Cerabar S, Deltabar S, Deltapilot S
Exchange of electronics on Cerabar S, Deltabar S, and Deltapilot S
FMB70-, FMD72-, FMD76-, FMD77-, FMD78-, PMC71-, PMD70-, PMD75-,
PMP71-, PMP72-, PMP75-Short Instruction (KA)04/12German , English -
Deltabar S FMD77, FMD78, PMD75
HART
Brief Operating Instructions
Differential pressure transmitter with metal sensors
Short Instruction (KA)03/18English -
Cerabar S, Deltabar S, Deltapilot S
Cearabar S - pressure transmitter
Deltabar S - differential pressure transmitter
Deltapilot S - hydrostatic level measurement
V02.30.zzShort Instruction (KA)02/18German , English -
Harting plug HAN7D
Installation instruction
Cerabar M/S, Deltabar M/S, Deltapilot M/S
Mounting Instruction (EA) -
Cable separate version
Installation Instructions
Cerabar M, Cerabar S, Deltabar S, Deltapilot M, Deltapilot S
Mounting Instruction (EA) -
Terminal module
Installation Instructions
Cerabar S PMC71, PMP71, PMP75, Deltabar S FMD77, FMD78, PMD75, Deltabar
FMD71, FMD72, Deltapilot S FMB70Mounting Instruction (EA) -
Aluminum housing T15
Installation instruction
Deltabar S, Deltapilot S
Mounting Instruction (EA) -
Aluminum housing T14
Installation instruction
Cerabar S, Deltabar S, Deltapilot S
Mounting Instruction (EA) -
Display
Installation Instruction
Cerabar S, Deltabar, Deltabar S, Deltapilot S
Mounting Instruction (EA) -
Push button housing
Installation instruction
Cerabar S, Deltabar S, Deltapilot S
Mounting Instruction (EA) -
Installation instruction - Ground terminal T14/T15/T17, F30/F31
Cerabar S, Deltabar S, Deltabar, Cerabar M, Deltabar M, Deltapilot M
Mounting Instruction (EA) -
Mounting set for housing T14/15
Installation instruction
Cerabar S, Deltabar S, Deltapilot S
Mounting Instruction (EA) -
Feed-through and adapter for T15
Installation Instruction
Cerabar S, Deltabar S, Deltapilot S
Mounting Instruction (EA) -
Electronics
Installation Instructions
Cerabar S PMC71, PMP71, PMP75, Deltabar S FMD77, FMD78, PMD75, Deltabar
FMD71, FMD72, Deltapilot S FMB70Mounting Instruction (EA) -
Installation Instructions
Gasket with metal ring for universal process adapter
Deltapilot M FMB50, Deltalpilot S FMB70, Deltabar FMD71, Deltabar S
FMD78, Cerabar M PMC51, Cerabar PMP23Mounting Instruction (EA) -
Deltabar S PMD75, FMD77, FMD78
ATEX:
II 1/2 G Ex ia IIC T6...T4 Ga/Gb
II 2 G Ex d IIC T6...T4 Gb
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD75, FMD77, FMD78
FM Control Drawing
960006404 C
IS+XP, NI, DIPEx Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD70, PMD75, FMD76, FMD77, FMD78
FM Control Drawing
960006696 F
IS, NI, DIPEx Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD75, FMD77, FMD78
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex d IIC T Gb
TÜV 13.0902X (INMETRO)Ex Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD70, PMD75, FMD76, FMD77, FMD78
Ex ia IIC T6...T4 Ga/Gb
IECEx KEM06.0011Ex Safety Instructions (XA) -
Deltabar S PMD70, PMD75, FMD77, FMD78
KEMA 03 ATEX 1561
II 1/3 D
Protection: Ex tD A20 IP67 T85°CEx Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
ATEX:
II 1 G Ex ia IIC T6...T4 Ga
II 1 D Ex ia IIIC T85°C Da
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Deltabar S PMD70, PMD75, FMD77, FMD78
KEMA 03 ATEX 1561
II 1/2 D
Protection: Ex tD A20 IP67 T105°CEx Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
ATEX:
II 2 G Ex db IIC T6...T4/T1 Gb
IECEx:
Ex db IIC T6...T4/T1 Gb
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
ATEX:
II 1/2 G Ex ia IIC T6...T4 Ga/Gb
IECEx:
Ex ia IIC T6...T4 Ga/Gb
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
EAC:
Ga/Gb Ex ia IIC T6...T4
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD75, FMD77, FMD78
Ex d IIC T6...T4 Gb
IECEx KEM 10.0031Ex Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD75, FMD77, FMD78
FM Control Drawing
XA01064P-B
NIEx Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
ATEX:
II 1/2 D Ex ta/tb IIIC T85°C Da/Db
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD70, PMD75, FMD76, FMD77, FMD78
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex nA IIC T6 Gc
GYJ14.1447 (NEPSI)Ex Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD75, FMD77, FMD78
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex ia IIC T4/T6 Ga/Gb
GYJ15.1274X (NEPSI)Ex Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
ATEX:
II 3 G Ex nA IIC T6 Gc
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD75, FMD77, FMD78
FM Control Drawing
XA01071P-B
XP, DIP, NIEx Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD70, PMD75, FMD77, FMD78
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex ta IIIC T130°C Da/Db (HART)
Ex ta IIIC T105°C Da/Db (PA, FF)
TÜV 13.2007 (INMETRO)Ex Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD75, FMD77/78
CSA Control Drawing
960006697 I
ISEx Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
ATEX:
II 1/2 G Ex ia IIC T6...T4 Ga/Gb
II 1/2 D Ex ia IIIC T85°C Da/Db
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Safety Instructions
Deltabar S FMD77, FMD78, PMD75
CSA Control Drawing
960008823 D
XPEx Safety Instructions (XA) -
Safety Instructions
Cerabar S PMP71, PMP75, Deltabar S PMD75, FMD77, FMD78
FM Control Drawing
960006753 C
IS+XP, NI, DIPEx Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
EAC:
Ga/Gb Ex ia IIC T6...T4
Ex ia IIIC T85°C Da/Db
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD70, PMD75, FMD76, FMD77, FMD78
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex ia IIC T6...T4 Ga/Gb
TÜV 13.2007 (INMETRO)Ex Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
ATEX:
II 1/3 D Ex ta/tc IIIC T85°C Da/Dc
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Cerabar S PMC71, PMP71, PMP75
Deltabar S FMD77, FMD78, PMD75
CSA Control Drawing
960006717 G
ISEx Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
EAC:
1Ex db IIC T6...T4 Gb
1Ex db IIC T6...T1 Gb
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD75, FMD77, FMD78
CSA Control Drawing
960006403 H
IS + XPEx Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
EAC:
Ex ta IIIC T85°C Da / Ex tc IIIC T85°C Dc
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Cerabar S PMP71, PMP72, PMP75
Deltabar S FMD77, FMD78, PMD75
CSA
Drawing No.: 960006752 F
Drawing Type: Control DrawingEx Safety Instructions (XA) -
Safety Instructions
Cerabar S PMC71, PMP71, PMP72, PMP75
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75
FM Control Drawing
960006703 E
ISEx Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD75, FMD77, FMD78
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex d IIC T4/T6 Gb
GYJ15.1272XEx Safety Instructions (XA) -
RFID TAG
Certificate/Declaration of Conformity
ATEX:
II 2 G Ex ia IIC T6 Gb
II 2 D Ex ia IIIC T80°C Db;
IECEx:
Ex ia IIC T6 Gb
Ex ia IIIC T80°C Db
IECEx EPS 15.0042X; EPS 15 ATEX 1 1011 XCertificate (ZE) -
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75
Allgemeine bauaufsichtliche Zulassung Z-65.11-384
Certificate (ZE) -
Certificate of compliance
EHEDG
Cerabar M, Cerabar S, Deltabar S, Deltabar
Certificate No. PE 14-9604Certificate (ZE) -
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75
CSA
Drawing No.: 960534-2092 B
Drawing Type: Control Drawing
4...20 mA HARTCertificate FM/CSA (ZD) -
Cerabar S, Deltabar S PMP71, PMP72, PMP75, FMD77, FMD78, PMD75
FM
Drawing No.: 960006753 A
Drawing Type: Control Drawing
PROFIBUS PA, FOUNDATION FieldbusCertificate FM/CSA (ZD) -
Cerabar S, Deltabar S PMP71, PMP72, PMP75, FMD77, FMD78, PMD75
CSA
Drawing No.: 960006752 A
Drawing Type: Control Drawing
PROFIBUS PA, FOUNDATION FieldbusCertificate FM/CSA (ZD) -
Cerabar S, Deltabar S PMC71, PMP71, PMP72, PMP75, FMD76, FMD77, FMD78,
PMD70, PMD75
FM
Drawing No.: 960006703 C
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Cerabar S PMP71, PMP72, PMP75
Deltabar S FMD77, FMD78, PMD75
CSA
Drawing No.: 960006752 C
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Cerabar S, Deltabar S PMC71, PMP71, PMP72, PMP75, FMD76, FMD77, FMD78,
PMD70, PMD75
CSA
Drawing No.: 960006717 A
Drawing Type: Control Drawing
PROFIBUS PA, FOUNDATION FieldbusCertificate FM/CSA (ZD) -
Deltabar S FMD77, FMD78, PMD75
CSA
Drawing No.: 960534-2098 B
Drawing Type: Control Drawing
4...20 mA HARTCertificate FM/CSA (ZD) -
Cerabar S, Deltabar S PMC71, PMP71, PMP72, PMP75, FMD76, FMD77, FMD78,
PMD70, PMD75
FM
Drawing No.: 960006703 A
Drawing Type: Control Drawing
PROFIBUS PA, FOUNDATION FieldbusCertificate FM/CSA (ZD) -
Cerabar S, Deltabar S PMC71, PMP71, PMP75, FMD76, FMD77, FMD78, PMD70,
PMD75
CSA
Drawing No.: 960006717 D
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75
FM
Drawing No.: 960534-1092 B
Drawing Type: Control Drawing
4...20 mA HARTCertificate FM/CSA (ZD) -
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75
CSA
Drawing No.: 960534-2092 D
Drawing Type: Control Drawing
4...20 mA HARTCertificate FM/CSA (ZD) -
Deltabar S FMD77, FMD78, PMD75
CSA
Drawing No.: 960006403 D
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75
FM
Drawing No.: 960534-1092 D
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Deltabar S FMD77, FMD78, PMD75
CSA
Drawing No.: 960008823 A
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75
CSA
Drawing No.: 960006697 E
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Deltabar S FMD77, FMD78, PMD75
FM
Drawing No.: 960006404 A
Drawing Type: Control Drawing
4...20 mA HARTCertificate FM/CSA (ZD) -
Cerabar S, Deltabar S PMC71, PMP71, PMP72, PMP75, FMD76, FMD77, FMD78,
PMD70, PMD75
CSA
Drawing No.: 960006717 C
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Functional Safety Manual
Deltabar S PMD75, FMD77, FMD78
Pressure and Differential Pressure, Level and Flow Measurement
with Output Signal 4...20 mASpecial Documentation (SD) -
Pressure Equipment Directive (PED)
Pressure measurement
Special Documentation
Pressure Equipment Directive (PED)
Special Documentation (SD) -
Interoperability Statement: Deltabar S (Evolution), FOUNDATION fieldbus
Endress+Hauser field device has been tested with Rockwell Automation
Integrated Architecture-based host system Allen-Bradley ControlLogix.
Deltabar S (Evolution), FOUNDATION fieldbus Pressure Transmitter, Device
Revision: 5, DD Revision: 1, Device ID: 0x1009, Software Revision: 2.00Special Documentation (SD) -
Deltabar S PMD70/75, FMD76/77/78
Functional Safety data sheet / Datenblatt zur Funktionalen Sicherheit
Special Documentation (SD) -
Mechanical accessories for pressure measuring devices
Pressure measurement
Special Documentation
Mechanical accessories for pressure measuring devices
Special Documentation (SD) -
Application conditions for seals and plastics in the food sector
Level measurement, pressure measurement
Special Documentation
Application conditions for seals and plastics in the food sector
Special Documentation (SD) -
RFID TAG
Special Documentation
RFID TAG
Special DocumentationSpecial Documentation (SD) -
Cerabar S, Cerabar M, Deltabar S
PMC71, PMP72, PMP75, PMP55,
FMD77, FMD78
Erklärung zur Druckgeräterichtlinie
Declaration to Pressure Equipment Directive
Déclaration relative à la Directive Equipements sous PressionSpecial Documentation (SD) -
Deltabar S PMD70, PMD75, FMD76, FMD77, FMD78
Cerabar S PMC71, PMP71, PMP75
Manufacturer Information for users regarding software updates (NE53)
Software version 02.10.40
Manufacturer Information (MI) -
Deltabar S: PMD75, FMD77, FMD78,
Cerabar S: PMC71, PMP71, PMP75,
Deltapilot S: FMB70
Manufacturer information for users regarding software updates (NE53)
Firmware V02.30.06, HART
Manufacturer Information (MI) -
Deltabar S: FMD76, FMD77, FMD78, PMD70, PMD75
Manufacturer information for users regarding software updates (NE53)
Software version V02.11.00 HART
Manufacturer Information (MI) -
PRM FOUNDATION fieldbus Package V1.05.00
Manufacturer Information includes PRM - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.05.00Manufacturer Information (MI) -
Simatic PDM PROFIBUS Package V1.12.00
Manufacturer Information includes PDM - Device List, Release Notes –
PROFIBUS
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Manufacturer Information (MI) -
Deltabar S: FMD76, FMD77, FMD78, PMD70, PMD75
Manufacturer information for users regarding softwareupdates (NE53)
Software version V04.01.00 PA
Manufacturer Information (MI) -
AMS FOUNDATION fieldbus Package V1.06.00
Manufacturer Information includes AMS - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.06.00Manufacturer Information (MI) -
Cerabar S PMC71, PMP71, PMP75,
Deltabar S PMD70, PMD75, FMD76, FMD77, FMD78
Manufacturer Information for users regarding softwareupdates (NE53)
Software version V03.00.00 / DevRev 6 FOUNDATION FIELDBUS
Manufacturer Information (MI) -
Please fill in. (You can find example text among the HELP menu)
Please fill in. (You can find example text among the HELP menu)
Manufacturer Information (MI) -
Deltabar S PMD70, PMD75, FMD76, FMD77, FMD78
Cerabar S PMC71, PMP71, PMP75
Manufacturer Information for users regarding software updates (NE53)
Software version V4.00.10 PROFIBUS PA
Manufacturer Information (MI) -
PRM HART Package V1.08.00
Manufacturer Information includes PRM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.08.00Manufacturer Information (MI) -
Deltabar S: FMD76, FMD77, FMD78, PMD70, PMD75
Manufacturer information for users regarding software updates (NE53)
Software version V04.00.01 FF
Manufacturer Information (MI) -
AMS HART Package V1.12.00
Manufacturer Information includes AMS - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Manufacturer Information (MI) -
Please fill in. (You can find example text among the HELP menu)
Please fill in. (You can find example text among the HELP menu)
Manufacturer Information (MI) -
Simatic PDM HART Package 1.14.00
Manufacturer Information includes PDM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.14.00Manufacturer Information (MI) -
Deltabar S: FMD77, FMD78, PMD75
Manufacturer information for users regarding software updates (NE53)
Softwareversion V02.20.00 HART
Manufacturer Information (MI) -
Control Engineering marzec 2006
Akredytowana kalibracja przetworników ci&
347;nienia i ró
&
380;nicy ci&
347;nie&
324;Publications (PU)09/08Polish -
Nap&
281;dy i Sterowanie marzec 2007
Akredytowana kalibracja przetworników
ci&
347;nienia i ró&
380;nicy ci&
347;nie&
324;Publications (PU)08/09Polish -
压力测量
用于过程压力、差压、液位和流量测量的专业仪表
Fields of Activities (FA)09/15Chinese -
Basınç Ölçümü
Proses basıncı, fark basınç, seviye ve akış için güçlü enstrümanlar
Fields of Activities (FA)05/15Turkish -
Mesure de niveau
Aperçu des produits pour des applications dans des liquides et des
solides en vracFields of Activities (FA)03/19fr -
Misura della pressione
Potenti strumenti per la misura della pressione di processo, pressione
differenziale,
livello e portataFields of Activities (FA)03/17Italian -
Catálogo Medición de Presión
Instrumentos para la medición de presión, presión diferencial, nivel y
caudal de procesoFields of Activities (FA)03/17Spanish -
Level measurement
Product overview for applications in liquids and bulk solids
Fields of Activities (FA)03/17English -
Catálogo Medición y Detección de nivel
Gama de productos para aplicaciones con líquidos y sólidos
Fields of Activities (FA)03/17Spanish -
Druckmesstechnik
Leistungsfähige Messgeräte für Prozessdruck, Differenzdruck, Füllstand
und DurchflussFields of Activities (FA)03/17German -
Mesure de pression
Appareils de mesure pour la pression de process, la pression
différentielle, le niveau et le débitFields of Activities (FA)03/17fr -
Pressure measurement
Powerful instruments for process pressure, differential pressure, level
and flowFields of Activities (FA)03/17English -
Füllstandmesstechnik
Produktübersicht für Anwendungen in Flüssigkeiten und Schüttgütern
Fields of Activities (FA)03/17German -
Level measurement
Product overview for applications in liquids and bulk solids
Fields of Activities (FA)03/17English -
Pressure measurement
American version: Powerful instruments for process pressure,
differential pressure, level
and flowFields of Activities (FA)03/17English -
Pomiar ciśnienia
Potężna aparatura do pomiaru
ciśnienia procesowego, różnicy
ciśnień, poziomu i przepływuFields of Activities (FA)03/14Polish -
Selection Guide
Continuous level measurement in liquids and bulk solids
Selection and engineering guide for the process industry
Competence Brochure (CP)12/17English -
Mesure de niveau continue dans les liquides et les solides
Sélection et configuration pour l'industrie des process
Competence Brochure (CP)12/17fr -
粉体液体の連続レベル測定
レベル計選定ガイド
Competence Brochure (CP)12/17Japanese -
Selection Guide, Auswahlhilfe.
Kontinuierliche Füllstandmessung in Flüssigkeiten und Schüttgütern
Auswahl- und Projektierungshilfe für die Prozessindustrie
Competence Brochure (CP)11/17German -
Komplettpaket Druckmesstechnik
Ein Ansprechpartner - spart Zeit und reduziert Kosten
Competence Brochure (CP)05/15German -
Непрерывное измерение уровня жидких и сыпучих продуктов
Руководство по подбору обоурдования
Competence Brochure (CP)03/13Russian -
American version: Continuous level measurement in liquids and bulk
solids
American version: Selection and engineering guide for the process
industryCompetence Brochure (CP)English -
Ofenreparatur mit Mehrwert
Messtechnik für eine effizientere Grobblechveredelung
Wenn
s heiß hergeht, wie z. B. beim
Härten, Anlassen und Vergüten von
Grobblechen in Durchlaufglühöfen,
ist robuste Messtechnik gefragt.
Der Ofen der voestalpine Grobblech GmbH (voestalpine) hatte eine
Reparatur nötig, durch die neben der Erhöhung des Durchsatzes auch
der Energie- und Gasverbrauch reduziert
werden sollte. Dass Verbrennungsluft
wie auch Mischgas im bestmöglichen
Verhältnis zugeführt werden, stellt
heute ein komplettes Paket an Feldinstrumenten
von Endress+Hauser
sicher.Case Studies (CS)06/10German -
Differntial pressure measurement in thermo-mechanical pulp mill
Deltabar S FMD78 for high process temperatures
Case Studies (CS)01/10English -
Patented TempC Membrane
Best pressure measurement with diaphragm seals
Innovations (IN)08/17English -
Membrane TempC
Précision et sécurité maximales en mesure de pression avec séparateurs
à membraneInnovations (IN)07/14fr -
Innovation Brochure: TempC Membrane
Highest accuracy and process safety in pressure and differential
pressure measurement with diaphragm sealsInnovations (IN)07/14English -
TempC 膜片
专利的、低温度影响、高精度、高安全性的压力和差压测量隔离膜片
Innovations (IN)07/14Chinese -
Innovationsbroschüre: TempC Membrane
Höchste Genauigkeit und Prozesssicherheit bei der Druck- und
Differenzdruckmessung mit DruckmittlernInnovations (IN)07/14German -
Patentierte TempC Membran
Ein Garant für beste Messperformance
Innovations (IN)01/18German -
Deltabar S Differential Pressure Transmitter via
FOUNDATION fieldbus to the PlantPAx Process Automation System
System using a 1757-FFLD or FFLDC
Integration DocumentSystem Partner (SP)03/12English -
Deltabar S Transmitter via PROFIBUS PA to the PlantPAx Process
Automation System
System using a 1788HP-EN2PAR Linking Device
Integration DocumentSystem Partner (SP)01/13English -
Deltabar S Transmitter via HART to the PlantPAx Process Automation
System
System using a ControlLogix 1756 HART Analog Input Module
Integration DocumentSystem Partner (SP)01/09English -
GSD Single, GSD_EH_PA_PR_Deltabar_0x1542_V03_00_10_PALIB, 14.04.2014 (Pre
ssure, Deltabar S, 0x1542)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)3.00.10Language neutral -
GSD Single, GSD_EH_PA_PR_DeltabarS_0x1542_0x03_0x01_PALIB, 19.05.2014 (Pr
essure, Deltabar S, 0x1542)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDD Single, AMS11_5_FF_PR_DeltabarS_0x1009b_0x07_0x02, 11.04.2017 (Pressure, Deltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
AMS Version: 11.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_PR_DeltabarS_0x1009b_0x06_0x03_FFLIB_ITK5_20, 09.11.201
6 (Pressure, Deltabar S, 0
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 5.20Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_PR_DeltabarS_0x0017_0x17_0x01, 23.04.2018 (Pressure, Deltabar S, 0x0017)
HART,
PDM Version: 6.1, 9.0.1.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_PR_DeltabarS_0x0017_0x16_0x04, 31.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
Field Device Manager Version: R430.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_PR_DeltabarS_0x0017_0x15_0x04, 21.08.2019 (Pressure, Deltabar S, 0x0017)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_PR_DeltabarS_0x0017_0x16_0x03, 28.05.2015 (Pressure, Deltabar S)
HART,
PDM Version: 6.1, 8.1, 8.2.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_PR_DeltabarS_0x0017_0x0A_0x01, 06.11.2018 (Pressure, Deltabar S, 0x0017)
HART,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_PR_DeltabarS_0x0017_0x15_0x04, 21.08.2019 (Pressure, Deltabar S, 0x0017)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_PR_DeltabarS_0x1542_0x01_0x01, 04.01.2019 (Pressure, Deltabar S, 0x1542)
PROFIBUS PA,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_5_FF_PR_DeltabarS_0x1009b_0x07_0x02, 11.04.2017 (Pressure, Deltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
AMS Version: 10.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_PR_DeltabarS_0x1009b_0x06_0x01_FFLIB_ITK5_01, 09.11.201
6 (Pressure, Deltabar S, 0
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 5.01Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_5_HART_PR_DeltabarS_0x0017_0x16_0x04, 31.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Other, EDD_FF_PR_DeltabarS_0x1009b_0x07_0x02, 12.05.2014 (Pressure, D
eltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: AnyElectronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_HART_PR_DeltabarS_0x0017_0x17_0x02, 25.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
AMS Version: 10.0, 10.1, 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_PR_DeltabarS_0x0017_0x15_0x04, 31.03.2014 (Pressure,
Deltabar S, 0x0017)
HART,
Field Device Manager Version: R430.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_PR_DeltabarS_0x1542_0x03_0x02, 17.08.2015 (Pressure, Deltabar S)
PROFIBUS PA,
PDM Version: 6.0 SP5, 6.1, 8.1, 9.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_PR_DeltabarS_0x0017_0x14_0x02, 27.02.2018 (Pressure, Deltabar S, 0x0017)
HART,
PDM Version: 6.0 SP5, 9.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_0_HART_PR_DeltabarS_0x0017_0x16_0x04, 31.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_PR_DeltabarS_0x1009b_0x05_0x01_FFLIB_ITK4_60, 09.11.201
6 (Pressure, Deltabar S, 0
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 4.60Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_PR_DeltabarS_0x1542_0x01_0x02, 04.01.2019 (Pressure, Deltabar S, 0x1542)
PROFIBUS PA,
PDM Version: 6.0 SP3, 6.1, 8.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_0_FF_PR_DeltabarS_0x1009b_0x07_0x02, 11.04.2017 (Pressure, Deltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
AMS Version: 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_PR_DeltabarS_0x1009b_0x05_0x01_FFLIB_ITK4_61, 09.11.201
6 (Pressure, Deltabar S, 0
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 4.61Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_PR_DeltabarS_0x0017_0x17_0x02, 25.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
Experion Version: R432.1
Field Device Manager Version: R450.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_0_HART_PR_DeltabarS_0x0017_0x17_0x02, 25.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS13_0_FF_PR_DeltabarS_0x1009b_0x07_0x02, 11.04.2017 (Pressure, Deltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
AMS Version: 13.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_PR_DeltabarS_0x0017_0x15_0x07, 25.02.2015 (Pressure,
Deltabar S, 0x0017)
HART,
PDM Version: 6.0 SP5, 6.1, 8.1, 8.1 SP1Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, DeltabarS_xMD7x_FF_FW4_00_zz_Dev_Rev_7, 08.07.2019 (Pressure, Deltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.06.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00
FieldMate Version: 2.05
Plant Resource Manager Version: R3.10Device Type Manager (DTM)1.6.55.40Language neutral -
DTM Single, DeltabarS_PMx7x_FF_V3_00_xx_DevRev6, 08.07.2019 (Pressure, Deltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.6.55.40Language neutral -
DTM Single, DeltabarS_xMD7x_PA_FW4_01_zz_Dev_Rev_3, 08.07.2019 (Pressure, Deltabar S, 0x1542)
PROFIBUS PA,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.5.155.349Language neutral -
DTM Single, DeltabarS_xMD7x_PA_V4_00_xx, 08.07.2019 (Pressure, Deltabar S, 0x1542)
PROFIBUS PA,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, DeltabarS_xMD7x_PA_V03_00_10, 08.07.2019 (Pressure, Deltabar S, 0x1542)
PROFIBUS PA,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, DeltabarS_xMD7x_HART_FW_2_30_zz_Dev_Rev_23, 08.07.2019 (Pressure, Deltabar S, 0x0017)
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.06.00
Field Device Manager Version: R450.1
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00
PACTware Version: 5.0 SP4
Plant Resource Manager Version: R3.31Device Type Manager (DTM)1.4.189.51Language neutral -
DTM Single, DeltabarS_xMD7x_HART_FW2_20_zz_Dev_Rev_22, 08.07.2019 (Pressure, Deltabar S, 0x0017)
HART,
DeviceCare Version: 1.06.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00
Plant Resource Manager Version: R3.11, R3.12Device Type Manager (DTM)1.4.189.51Language neutral -
DTM Single, DeltabarS_xMD7x_V02_10_xx, 08.07.2019 (Pressure, Deltabar S, 0x0017)
HART,
DeviceCare Version: 1.06.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00
Plant Resource Manager Version: R3.11Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, DeltabarS_xMD7x_V01_00, 08.07.2019 (Pressure, Deltabar S, 0x0017)
HART,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, DeltabarS_xMD7x_V02_00, 08.07.2019 (Pressure, Deltabar S, 0x0017)
HART,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.4.188.39Language neutral -
Faceplate Library, PRM_HART_Package_Pressure_1_08_00, 22.07.2015 (Pressur
e)
HART,
Plant Resource Manager Version: R3.05, R3.11, R3.12Faceplate1.08.00Language neutral -
Faceplate Library, PRM_FF_Package_Pressure_1_05_00, 29.05.2018 (Pressure)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.02Faceplate1.05.00Language neutral -
Faceplate Single, PRM_HART_PR_DeltabarS_0x0017_0x16_0x04, 31.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
Plant Resource Manager Version: R3.12Faceplate1.00.00Language neutral -
Faceplate Single, PRM_FF_PR_DeltabarS_0x1009b_0x07_0x02, 07.04.2014 (Pres
sure, Deltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.11Faceplate1.00.00Language neutral -
Faceplate Single, PRM_HART_PR_DeltabarS_0x0017_0x17_0x02, 25.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
Plant Resource Manager Version: R3.31Faceplate1.00.00Language neutral -
Animation TempC Membrane
Animation FR 1920x1080 mp4
Animation11/14German -
Animation TempC Membrane
Animation IT 1920x1080 mp4
Animation09/16Italian -
Animation TempC Membrane
Animation PT 1920x1080 mp4
Animation06/15Portuguese -
Animation TempC Membrane
Animation ES 1280x720 mp4
Animation04/16Spanish -
Animation TempC Membrane
Animation RU 1920x1080 mp4
Video03/17Russian -
Cerabar S, Deltabar S, Levelflex
Product Code: FMD78-, FMP51-, PMD75-, PMP71-, PMP75-
Declaration Number: HE_00913_02.17
Manufacturer Specification: Explosion protectionManufacturer DeclarationEnglish -
Deltapilot S, Deltapilot M, Deltabar S, Deltabar M, Deltabar, Ceraphant, Cerabar S, Cerabar M, Cerabar
Product Code: PTP33B-, PMP71-, PMP55-, PMP51-, PMP23-, PMD75-, PMD55-, FMD78-, FMD77-, FMD72-, FMB70-, FMB52-, FMB51-, FMB50-
Declaration Number: HE_01110_02.19
Manufacturer Specification: Food hygieneManufacturer DeclarationEnglish -
Deltapilot S, Deltapilot M, Deltabar S, Deltabar M, Deltabar, Ceraphant, Cerabar S, Cerabar M, Cerabar
Product Code: PTP33B-, PMP71-, PMP55-, PMP51-, PMP23-, PMD75-, PMD55-, FMD78-, FMD77-, FMD72-, FMB70-, FMB52-, FMB51-, FMB50-
Declaration Number: HE_01110_01.19
Manufacturer Specification: Food hygieneManufacturer DeclarationEnglish -
Cerabar S, Deltabar S, Deltapilot S
Product Code: FMB70-, FMD76-, FMD77-, FMD78-, PMC71-, PMD70-, PMD75-, PMP71-, PMP72-, PMP75-
Declaration Number: HE_00729_01.17Manufacturer DeclarationGerman , English -
Cerabar S, Deltabar, Deltabar S
Product Code: FMD77-, FMD78-, PMD75B-, PMP71-, PMP75-
Declaration Number: HE_00999_01.18
Manufacturer Specification: Operating conditionsManufacturer DeclarationEnglish -
Deltabar S
Product Code: FMD78-
Declaration Number: HE_00580_01.17
Manufacturer Specification: RoHSManufacturer DeclarationChinese -
Deltabar S
Product Code: FMD78-
Declaration Number: HE_01183_01.19Manufacturer DeclarationGerman , English -
Deltapilot S, Deltapilot M, Deltabar S, Deltabar M, Deltabar, Ceraphant, Cerabar S, Cerabar M, Cerabar
Product Code: PTP33B-, PMP71-, PMP55-, PMP51-, PMP23-, PMD75-, PMD55-, FMD78-, FMD77-, FMD72-, FMB70-, FMB52-, FMB51-, FMB50-
Declaration Number: HE_01110_03.19
Manufacturer Specification: Food hygieneManufacturer DeclarationEnglish -
Deltabar S, Levelflex, Liquicap M, Liquiphant M, Micropilot
Product Code: FTL51H-, FTL50H-, FTI51-, FMR52-, FMP52-, FMI51-, FMD78-
Declaration Number: HE_00916_01.18
Manufacturer Specification: EHEDGManufacturer DeclarationGerman , English -
Deltabar S
Product Code: FMD78-
Declaration Number: HE_00214_01.15
Manufacturer Specification: Food hygiene, 10/2011, 1935/2004Manufacturer DeclarationGerman , English -
Deltabar S
Product Code: FMD77-, FMD78-, PMD75-
Declaration Number: EC_00515_02.17EU DeclarationGerman , English , fr -
Deltabar S
Product Code: FMD77-, FMD78-, PMD75-
Declaration Number: EC_00516_02.17EU DeclarationGerman , English , fr -
Deltabar S
Product Code: PMD75-, FMD78-, FMD77-
Declaration Number: EC_00514_02.17EU DeclarationGerman , English , fr -
Deltabar S
Product Code: FMD76-, FMD77-, FMD78-, PMD70-, PMD75-
EU DeclarationGerman , English , fr -
Deltabar S
Product Code: FMD77-, FMD78-, PMD75-
Declaration Number: EC_00250_03.16EU DeclarationGerman , English , fr -
Deltabar S
Product Code: FMD77-, FMD78-
Declaration Number: EC_00513_03.17EU DeclarationGerman , English , fr -
Deltabar S
Product Code: FMD78-, PMD75-, FMD77-
Declaration Number: EC_00517_02.17EU DeclarationGerman , English , fr -
Deltabar M, Deltabar S
Product Code: FMD76-, FMD77-, FMD78-, PMD55-, PMD70-, PMD75-
Region/Country: Russia
Approval Agency: Rostekhnadzor
Approval Number: 01-TY-00477-2014MiscellaneousRussian -
Deltabar S
Product Code: FMD76-, FMD77-, FMD78-, PMD70-, PMD75-
Region/Country: China
Approval Agency: ACMA
Approval Number: EC11012AMiscellaneousEnglish -
Waterpilot, Deltapilot S, Deltapilot M, Deltapilot, Deltabar S, Deltabar M, Deltabar, Ceraphant T, Ceraphant, Cerabar T, Cerabar S, Cerabar M, Cerabar
Product Code: PTP33B-, PTP31B-, PTC31B-, PTC31-, PMP75-, PMP71-, PMP55-, PMP51-, PMP23-, PMP21-, PMP11-, PMD75-, PMD55-, PMC71-, PMC51-, PMC21-, PMC131-, PMC11-, FMX21-, FMX167-, FMD78-, FMD77-, FMB70-, FMB53-, FMB52-, FMB51-, FMB50-
Region/Country: Russia (TR CU), Russia (Declaration of Conformity)
Approval Agency: EAC
Approval Number: RU D-DE.MO10.B.05287MiscellaneousRussian -
Deltabar, Deltabar M, Deltabar S
Product Code: FMD71-, FMD72-, FMD77-, FMD78-, PMD55-, PMD75-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC BY_112 11.01. TP020 003 127MiscellaneousRussian -
Cerabar S, Deltabar S
Product Code: FMD77-, FMD78-, PMP71-, PMD75-, PMP75-, PMP72-
Region/Country: India
Approval Agency: CC(O)E
Protection: Ex iaExplosion ProtectionEnglish -
Cerabar S, Deltabar S
Product Code: FMD77-, FMD78-, PMD75-, PMP71-, PMP72-, PMP75-
Region/Country: South Korea
Approval Agency: KTL
Protection: Ex ia IIC T6...T2Explosion ProtectionGerman , English -
Cerabar S, Deltabar S
Product Code: FMD77-, FMD78-, PMC71-, PMD75-, PMP71-, PMP75-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Protection: Ex ta/tc, Ex ia, Ex dExplosion ProtectionRussian -
Deltabar S
Product Code: FMD77-, FMD78-, PMD75-
Region/Country: International, International (IECEx)
Approval Agency: DEKRA
Protection: Ex d IIC T6Explosion ProtectionEnglish -
Deltabar S
Product Code: PMD75-, FMD78-, FMD77-
Region/Country: Europe (ATEX)
Approval Agency: KEMA
Category: II 2 G
Protection: Ex d IIC T6 GbExplosion ProtectionEnglish -
Cerabar S, Deltabar S
Product Code: FMD77-, FMD78-, PMC71-, PMD75-, PMP71-, PMP75-
Region/Country: USA
Approval Agency: FM
Category: I,II,III/1/A,B,C,D,E,F,G/T6
Protection: XP/NI/DIP, XP/ISExplosion ProtectionEnglish -
Cerabar S, Deltabar S, Deltapilot S
Product Code: PMP71-, PMP75-, PMD75-, FMD78-, FMD77-, PMD70-, FMB70-, PMC71-
Region/Country: Brazil
Approval Agency: TÜV
Protection: Ex iaExplosion ProtectionPortuguese -
Deltabar S
Product Code: PMD75-, PMD70-, FMD78-, FMD77-, FMD76-
Region/Country: Europe (ATEX)
Approval Agency: KEMA
Category: II 1 D, II 1 G
Protection: Ex ia IIC T6 Ga/GbExplosion ProtectionEnglish -
Cerabar S, Deltabar S, Deltapilot S
Product Code: PMP75-, PMP71-, PMD75-, PMC71-, FMD78-, FMD77-, FMB70-
Region/Country: Europe (ATEX)
Approval Agency: DEKRA
Category: II 1/3 D, II 1/2 G, II 1/2 D, II 2 G
Protection: Ex ta/tb IIIC Txxx°C Da/Db, Ex ia IIIC Txxx°C Da/Db, Ex ia IIC T6 Ga/GbExplosion ProtectionEnglish -
Cerabar S, Deltabar S
Product Code: FMD77-, FMD78-, PMC71-, PMD75-, PMP71-, PMP75-
Region/Country: Europe (ATEX)
Approval Agency: DEKRA
Category: II 2 G
Protection: Ex d [ia] IIC T6...T3 Gb, Ex db IIC T6...T1 GbExplosion ProtectionEnglish -
Deltabar S
Product Code: FMD76-, FMD77-, FMD78-, PMD70-, PMD75-
Region/Country: China
Approval Agency: NEPSI
Protection: Ex ia IIC T6 Ga/GbExplosion ProtectionEnglish , Chinese -
Cerabar S, Deltabar S
Product Code: FMD77-, FMD78-, PMC71-, PMD75-, PMP71-, PMP75-
Region/Country: International (IECEx)
Approval Agency: DEKRA
Protection: Ex d [ia] IIC T6...T3 Gb, Ex db IIC T6...T1 GbExplosion ProtectionEnglish -
Cerabar S, Deltabar S, Deltapilot S
Product Code: FMB70-, FMD77-, FMD78-, PMC71-, PMD75-, PMP71-, PMP75-
Region/Country: USA
Approval Agency: FM
Category: I,II,III/1,2/A,B,C,D,F,G/
Protection: DIP, IS, NIExplosion ProtectionEnglish -
Deltabar S
Product Code: PMD75-, FMD78-, FMD77-
Region/Country: Europe (ATEX)
Approval Agency: KEMA
Category: II 2 G, II 1/2 G
Protection: Ex d IIC T6, Ex ia IIC T6Explosion ProtectionEnglish -
Deltabar S
Product Code: FMD77-, FMD78-, PMD75-
Region/Country: China
Approval Agency: NEPSI
Protection: Ex d IIC T6 GbExplosion ProtectionEnglish , Chinese -
Cerabar S, Deltabar S, Deltapilot S
Product Code: FMB70-, FMD77-, FMD78-, PMC71-, PMD75-, PMP71-, PMP75-
Region/Country: International (IECEx)
Approval Agency: DEKRA
Protection: Ex ia IIC T6 Ga/GbExplosion ProtectionEnglish -
Cerabar S, Deltabar S
Product Code: FMD77-, FMD78-, PMC71-, PMD75-, PMP71-, PMP75-
Region/Country: Brazil
Approval Agency: TÜV
Protection: Ex dExplosion ProtectionPortuguese -
Cerabar S, Deltabar S, Deltapilot S
Product Code: FMB70-, FMD77-, FMD78-, PMC71-, PMD75-, PMP71-, PMP75-
Region/Country: Canada, USA
Approval Agency: CSA
Category: II,III/1/E,F,G, I,II,III/1/B,C,D,E,F T6, I,II,III/1/A,B,C,D,E,F,G T6, I/2/A,B,C,D
Protection: XP/IS, XP, NI, IS/NI/DIP, DIPExplosion ProtectionEnglish -
Cerabar S, Deltabar S
Product Code: FMD77-, FMD78-, PMD75-, PMP71-, PMP72-, PMP75-
Region/Country: South Korea
Approval Agency: KTL
Protection: Ex d IIC T6...T2, Ex ia IIC T6...T2Explosion ProtectionGerman , English -
Cerabar S, Deltabar S
Product Code: PMP71-, PMP75-, PMC71-, FMD78-, PMD75-, FMD77-
Region/Country: Brazil
Approval Agency: TÜV
Protection: Ex dExplosion ProtectionPortuguese -
Cerabar S, Deltabar M, Deltabar S
Product Code: PMP75-, PMP72-, PMP71-, PMD75-, PMD70-, PMD55-, PMC71-, FMD78-, FMD77-, FMD76-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Protection: Ex d, Ex ia, Ex iaD 20, Ex taExplosion ProtectionRussian -
Deltabar S
Product Code: FMD78-
Region/Country: Europe
Approval Agency: TNO
Category: SANITARY
Protection: EHEDGHygienic EquipmentEnglish -
Prosonic S, Nivector, Micropilot, LIQUITREND, Liquipoint, Liquiphant M, Liquicap M, Levelflex, Deltapilot S, Deltapilot M, Deltabar S, Deltabar, Ceraphant, Cerabar T, Cerabar S, Cerabar M, Cerabar
Product Code: FTI52-, FTL33-, FTL330H-, FTL330L-, FTL50H-, FTL51H-, FTW23-, FTW33-, OTL330H-, OTP35-, PMC51-, PMC71-, PMP135-, PMP23-, PMP51-, PMP55-, PMP75-, PTP33B-, QMW43-, FDL60-, FDL61-, FDU91F-, FMB50-, FMB70-, FMD71-, FMD72-, FMD78-, FMI51-, FMI52-, FMP41C-, FMP43-, FMP52-, FMP53-, FMR245-, FMR52-, FMR62-, FTI26-, FTI51-
Region/Country: USA
Approval Agency: 3-A Sanitary StandardsHygienic EquipmentEnglish -
Deltabar S
Product Code: FMD76-, FMD77-, FMD78-, PMD70-, PMD75-
Region/Country: Germany
Approval Agency: DIBt
Approval Number: Z-65.11-384Overfill PreventionGerman -
Product Family: Deltabar S
Product Code: FMD76-, FMD78-, PMD75-, FMD77-, PMD70-
Region/Country: International
Approval Agency: Fieldbus Foundation
Software Version: DEVICE REV. 06, DD-ITK 5.20Fieldbus ConformanceEnglish -
Product Family: Deltabar S
Product Code: FMD76-, FMD78-, PMD75-, FMD77-, PMD70-
Region/Country: International
Approval Agency: Fieldbus Foundation
Software Version: DEVICE REV. 06, DD-ITK 5.01Fieldbus ConformanceEnglish -
Product Family: Deltabar S
Product Code: FMD76-, FMD78-, PMD75-, FMD77-, PMD70-
Region/Country: International
Approval Agency: Fieldbus Foundation
Software Version: DEVICE REV. 07, DD-ITK 6.10Fieldbus ConformanceEnglish -
Product Family: Deltabar S
Product Code: FMD76-, FMD78-, PMD75-, FMD77-, PMD70-
Region/Country: International
Approval Agency: PI, PROFIBUS International
Software Version: PROFILE 3.02Fieldbus ConformanceEnglish -
Waterpilot, Deltabar S, Cerabar S, Cerabar M, Deltapilot S, Deltabar M, Deltapilot M, Deltabar, Ceraphant T, Ceraphant, Cerabar T, Cerabar
Product Code: PTP35-, FMD78-, PMP71-, PMD75-, FMD77-, PMD70-, PMP75-, PMP51-, PMP55-, PMC71-, FMD76-, FMB53-, FMB70-, PMC51-, PMD55-, FMB50-, FMD72-, FMX21-, PTP33B-, PTP31-, PTC31-, PMP23-, PMP135-, PMP11-, PMC131-, FMX167-, FMD71-
Approval Agency: TÜVPressure EquipmentGerman , English -
Deltabar S
Product Code: FMD76-, FMD77-, FMD78-, PMD70-, PMD75-
Region/Country: Canada (CRN)
Approval Agency: CRNPressure EquipmentEnglish -
Levelflex, Deltabar S, Cerabar S, Cerabar M, Deltabar M, Ceraphant T, Ceraphant, Cerabar T, Cerabar
Product Code: PTP31B-, FMP54-, FMD78-, PMP71-, PMD75-, FMD77-, PMP75-, PMP51-, PMP55-, PMD55-, PTP31-, PMP21-, PMP135-, PMP131-
Approval Agency: TÜVPressure EquipmentGerman , English -
Deltapilot S, Deltapilot M, Deltabar S, Deltabar, Liquipoint, Liquiphant, Liquicap M, Liquiphant FailSafe, Liquiphant M, Levelflex, Ceraphant, Cerabar S, Cerabar M, Cerabar
Product Code: FMP53-, PMC51-, FMB50-, FMB70-, FMD71-, FMD78-, FTL33-, FTW33-, FTL81-, FTL80-, FTL51H-, FTL51-, FTL50H-, FTW23-, FTL50-, FTI52-, FTI51-, FMI52-, FMI51-, FTL31-, PTP33B-, PMP75-, PMP55-, PMP51-, PMP23-
Region/Country: Canada (CRN)
Approval Agency: CRNPressure EquipmentEnglish -
Deltabar, Deltabar M, Deltabar S
Product Code: FMD71-, FMD72-, FMD77-, FMD78-, PMD55-, PMD75-
Region/Country: Belarus
Approval Agency: BEL
Approval Number: 9770MetrologyRussian -
Deltabar M, Deltabar S
Product Code: FMD77-, FMD78-, PMD55-, PMD75-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: DE.C.30.004.A NO 71578MetrologyRussian -
Deltabar M, Deltabar S
Product Code: FMD77-, FMD78-, PMD55-
Region/Country:
Approval Agency: MSST
Approval Number: 2214MetrologyRussian -
Cerabar, Cerabar S, Deltabar S, Deltapilot S
Product Code: FMB70-, FMD77-, FMD78-, PMC71-, PMD75-, PMP71-, PMP75-
Region/Country: International
Approval Agency: TÜVSafety Integrity Level (SIL)English -
Cerabar S, Deltabar S
Product Code: PMP71-, PMC71-, PMP75-, FMD78-, PMD75-
Region/Country: International
Approval Agency: RM RSMarineRussian -
Deltabar S
Product Code: FMD78-, PMD75-
Approval Agency: BVMarineEnglish -
Deltabar S
Product Code: FMD78-, PMD75-
Region/Country: International
Approval Agency: ABSMarineEnglish -
Deltabar S
Product Code: FMD76-, FMD78-, PMD70-, PMD75-
Region/Country: International
Approval Agency: DNVGLMarineEnglish -
Deltabar S
Product Code: FMD76-, FMD78-, PMD70-, PMD75-
Region/Country: South Korea
Approval Agency: KRMarineEnglish -
Cerabar S, Deltabar S, Cerabar M, Deltabar
Product Code: PMP75-, FMD78-, PMP51-, PMP55-, FMD72-, PMP45-
Food SafetyEnglish
Accessories / Spare parts
-
-
Order code 71111056
Housing filter VA,EPDM,F15/31/T14/17,1pc
Consists of: vent screw 304. Pressure compensation filter. O-ring EPDM, protection lid. Usage: housing T14, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Housing F31, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55. Housing F15 w/o B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.
-
Order code 71219639
Housing filter VA, VMQ, F15, T17, 1 pc.
Consists of: vent screw 304. Pressure compensation filter. O-ring VMQ, protection lid. Usage: housing T17, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/ PMP75. Housing F15 bei B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.
-
-
-
Nr 15 Order code 52020760
Cable gland M20, gasket
Consists of: cable gland M20. O-ring 18.72x2.62 VMQ. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 15 Order code 52020761
Cable entry G1/2, gasket, adapter
Consists of: gasket 18.72x2.51 NBR. Adapter M20 > G1/2. O-ring 18.77x1.78 NBR. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 15 Order code 52020762
Plug 2/7-pole, HAN7D, gasket
Consists of: harting plug set. Usage: FMB50/FMB51/FMB52/FMB53, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD55, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.
-
Nr 15 Order code 52020763
Plug 3-pole, M12, gasket
Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 21 Order code 71206971
Sealing set FVQM, T14.5 pcs.
Consists of: 5x O-ring 75.87x2.62 FVMQ. Usage: housing T14, FMD77/FMD78, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 20 Order code 52020433
Cover T14/T15 Alu, Ex d, gasket
Material: aluminium, coated. O-ring EPDM, FDA. EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 20 Order code 52028310
Cover T14 316L, Ex d, EPDM
Material: 316L. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 20 Order code 71002774
Cover T17 316L, gasket
Material: 316L. Flat gasket EPDM, centering ring, screw. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 25 Order code 71002774
Cover T17 316L, gasket
Material: 316L. Flat gasket EPDM, centering ring, screw. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 20 Order code 71002810
Cover T17 316L, sight glass, gasket
Material: 316L. Sight glass: mineral glass. Flat gasket EPDM, centering ring, screw. For approval 2,3,4,7,8,Q,W. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. For approval BC,BD,IB. Usage: FMD71/FMD72.
-
Nr 20 Order code 71002811
Cover T17 316L, sight glass PC, gasket
Material: 316L. Sight glass: Polycarbonate PC. Flat gasket EPDM, centering ring, screw. For approval A,E,F,H,I,R,S,U,1,6. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. For approval AA,BA,CA,CB,CC,CD,FA,FB, FD,IA. Usage: FMD71/FMD72.
-
Nr 20 Order code 71206965
Cover T14 316L, Ex d, FVMQ
Material: 316L. O-ring FVMQ. Individual tested, EEx d/XP. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP72/PMP75.
-
Nr 20 Order code 71206968
Cover T14 316L, Ex d, sight glass, FVMQ
Material: 316L. Sight glass: mineral glass,coated. O-ring FVMQ. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 20 Order code 71245247
Cover T14/T15 Alu, sight glass, gasket
Material: aluminium, coated. Sight glass: mineral glass, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 20 Order code 71245249
Cover T14/T15 Alu,Exd,sight glass,gasket
Material: aluminium. Sight glass mineral glass, coated. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 20 Order code 52020432
Cover T14/T15 Alu, gasket
Material: aluminium, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 25 Order code 52020432
Cover T14/T15 Alu, gasket
Material: aluminium, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 25 Order code 52020433
Cover T14/T15 Alu, Ex d, gasket
Material: aluminium, coated. O-ring EPDM, FDA. EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 25 Order code 52028310
Cover T14 316L, Ex d, EPDM
Material: 316L. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 25 Order code 71206965
Cover T14 316L, Ex d, FVMQ
Material: 316L. O-ring FVMQ. Individual tested, EEx d/XP. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP72/PMP75.
-
-
-
Order code 71290825
Ground terminal T14/T15/T17, F30/F31
Consists of: spring washer, screw, earth handle, clamp. Usage: housing T14/T15/T17, FMB70, FMD71/FMD72/ FMD77/FMD78, PMC71, PMP71/PMP75, PMD70/PMD75. Housing F30/F31, FMB50/FMB51/FMB52/ FMB53, PMC51, PMD55, PMP51/PMP55.
-
-
-
Nr 21 Order code 52020429
Sealing EPDM, F30/31/34, T14/15, 5 pcs.
Consists of: 5x O-ring 75.87x2.62, EPDM, PTFE, FDA. Usage: housing F30/F31/F34, T14/T15.
-
-
-
Nr 20 Order code 71245250
Cover T14 316L, Ex d, sight glass, EPDM
Material: 316L. Sight glass: mineral glass, coated. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 30 Order code 52024111
Electronics HART Ex, ext. p. b., v2.0
4-20mA, version 2.0. Push button on housing. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 52024400
Electronics HART Ex, v2.0
4-20mA, version 2.0. Push button on electronics. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71026358
Electronics HART Ex, v2.10
4-20mA, version 02.10.zz. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71026359
Electronics HART Ex, ext. p. b., v2.10
4-20mA, version 02.10.zz. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 52026763
Upgrade electr. HART Ex,ext.push b.,v2.1
Consists of: electronics HART Ex, version 2.1. Push button external. Push button, housing HART version 2. Display housing. Usage: conversion electronics 1.0 > 2.1, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71196093
Electronics HART Ex, ext. p. b., v2.11
4-20mA, version 2.11.zz. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).
-
Nr 30 Order code 71071824
Electronics PA, HW02.00, SW4.0
PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.00.zz. Current consumption 13mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71071825
Electronics PA, ext. p.b., HW02.00,SW4.0
PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.00.zz. Current consumption 13mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71071826
Electronics FF, HW2.00, SW3.00
FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 15mA +/- 1mA. Push button on electronics. Verwendung: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71071827
Electronics FF, ext. p.b., HW2.00,SW3.00
FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 15mA +/- 1mA. Push button on housing. Verwendung: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71214890
Electronics FF, ext. p.b.,HW2.00, SW4.00
FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 04.00.zz, FF, DevRev07. Current consumption 15mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for SIL.
-
Nr 30 Order code 71214892
Electronics FF, HW2.00, SW4.00
FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 04.00.zz, FF, DevRev07. Current consumption 15mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for SIL.
-
Nr 30 Order code 71224775
Electronics PA, HW02.00, SW4.01
PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.01.zz, PROFIBUS PA, Profile 3.02, DevRev03. Current consumption 13mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71224776
Electronics PA, ext.p. b.,HW02.00,SW4.01
PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.01.zz, PROFIBUS PA, Profile 3.02, DevRev03. Current consumption 13mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 35 Order code 52020434
Terminal 3-pole, RFI, HART, TIIS
RFI-filter. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75, TIIS Ex ia.
-
Nr 35 Order code 52026605
Terminal 2-pole, RFI, PA, TIIS
RFI filter. PROFIBUS PA. Usage: FMB70, FMD76/FMD77/FMD78, PMD70/PMD75, PMP71/PMP75. TIIS Ex ia, TIIS Ex d. PMC71, TIIS Ex ia.
-
Nr 35 Order code 52027691
Terminal 2-pole, RFI, FF, Ex
RFI-filter. FOUNDATION Fieldbus. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 35 Order code 71028473
Terminal 3p., RFI, HART, OVP, TIIS
Overvoltage protection, RFI-filter. Usage: FMB70, FMD76/FMD77/FMD78, PMD70/PMD75, PMP71/PMP75.
-
Nr 35 Order code 71028475
Terminal 2-pole, RFI, PA, OVP, Ex
Overvoltage protection, RFI-filter. PROFIBUS PA. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 35 Order code 71028476
Terminal 2-pole, RFI, FF, OVP, Ex
Overvoltage protection, RFI-filter. FOUNDATION Fieldbus. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 35 Order code 71121574
Terminal 2-pole, RFI, PA, Ex
RFI filter. PROFIBUS PA. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for TIIS.
-
Nr 35 Order code 71191892
Terminal 3-pole,Li=0, RFI,HART,Ex ia/Exd
RFI-filter. Not for TIIS Ex ia, TIIS Ex d. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 35 Order code 71191894
Termin.3-p.,Li=0,RFI,HART,OVP,Ex ia/Exd
Overvoltage protection, RFI-filter. Not for TIIS Ex ia, TIIS Ex d. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 31 Order code 52027785
HistoROM / M-DAT, 16K
Setup-/diagnostic software included. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 40 Order code 71002865
Display module VU340, Cbar/Dbar/Dpilot S
Digital display, 3 push buttons, snapped bracket. Languages DE/EN/FR/ES/IT/NL, from software version 02.00.zz; Usage: electronics HART. Languages DE/EN/FR/ES/IT/NL/JA/ZH. From software version 02.01.zz; Electronics HART. Languages DE/EN/FR/ES/IT/JA/ZH/RU, from software version 02.11.zz; Electronics HART. From software version 04.00.zz; Electronics PROFIBUS PA. From software version 03.00.zz; Electronics FOUNDATION Fieldbus, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP72/PMP75. From software version 01.00.zz; Electronics HART, FMD71/FMD72.
-
-
-
Order code 52024609
Mounting set Deltabar S, 7/16-20UNF
Screws 7/16-20UNF, stainless steel. Material: 316L. Usage: wall/pipe mounting 2", FMD77/FMD78, PMD75.
-
Order code 943153-0031
-
Order code 71381907
Mounting kit standard, 7/16-20 UNF
Standard design. ::For non-vibrating applications. Material: 316L. Usage: wall/pipe mounting FMD78, PMD75.
-
Order code 71043886
Cable PE, L=2m/80inch, separate housing
Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.
-
Order code 71043888
Cable PE, L=5m/200inch, separate housing
Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.
-
Order code 71043889
Cable PE, L=10m/400inch,separate housing
Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.
-
Order code 71070738
Cable FEP, L=5m/200inch,separate housing
Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.
-
Order code 71007843
ToF Adapter FXA291
Usage: connection Micropilot M, Micropilot S, Levelflex M, Prosonic M, Tank Side Monitor, Deltabar S, Cerabar S, Gammapilot M, Micropilot I, to Commubox FXA291.
-
Order code 916743-0000
Weld-in adapter DRD DN50, 304
Flush mount process connection. Material: 304. Seal: PTFE flat. FDA compliant. Usage: Flush mount FTL50/FTL50H/FTL51/FTL51C/FTL51H, PMC51, PMP51, PMP55, PMC71, PMP75, FMB50, FMB70, FMD78.
-
Order code 71377370
Flushing ring NPS 2" Cl. 150-2500, 316L
Consists of: 2x flushing ring connection. Thread ASME FNPT 1/2. Usage: FMB70, FMD71/FMD72/FMD77/FMD78, PMC71, PMP55, PMP71/75.
-
Order code 71377371
Flushing ring NPS 3" Cl. 150-2500, 316L
Consists of: 2x flushing ring connection. Thread ASME FNPT 1/2. Usage: FMB70, FMD71/FMD72/FMD77/FMD78, PMC71, PMP55, PMP71/75.
-
Order code 71377380
Flushing ring DN50, PN16-400, 316L
Consists of: 2x flushing ring connection. Thread ASME FNPT 1/2. Usage: FMB70, FMD71/FMD72/FMD77/FMD78, PMC71, PMP55, PMP71/75.
-
Order code 71377383
Flushing ring DN80, PN16-400, 316L
Consists of: 2x flushing ring connection. Thread ASME FNPT 1/2. Usage: FMB70, FMD71/FMD72/FMD77/FMD78, PMC71, PMP55, PMP71/75.
-
Order code XPRFID-
-
-
Predecessor