Proline Promass A 500
Coriolis flowmeter
Accurate single-tube flowmeter for lowest flow rates, as remote version with up to 4 I/Os
The compact Promass A is ideal for continuous process control in very demanding applications. Its unique self-drainable single-tube system enables accurate measurement of liquids and gases at lowest flow rates and high pressure. With its innovative remote transmitter Promass A 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology ensures measurement reliability and compliant verification.
- F
- L
- E
- X
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Specs at a glance
-
Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 450 kg/h (0 to 16.54 lb/min)
-
Medium temperature range
-50 to 205 °C (-58 to 401 °F)
-
Max. process pressure
430.9 bar (6250 psi)
-
Wetted materials
Measuring tube: stainless steel, 1.4435 (316/316L); Alloy C22
-
Quick selection
Individual configuration
-
Benefits
Space-saving installation – compact, lightweight sensor
Highest product quality – self-drainable measuring tube design in all line sizes
Optimum process safety – resistant to corrosive ambient conditions and internal clogging
Full access to process and...
-
Field of application
Measuring principle operates independently of physical fluid properties such as viscosity or density
Suitable for applications with smallest flow quantities in all industries.
Device properties
Nominal diameter: DN 1 to 4 (1/24 to 1/8")
Process...
Documents / Manuals / Software
-
Proline Promass A 500
Coriolis flowmeter
Technical Information (TI) -
Proline Promass A 500
FOUNDATION Fieldbus
Coriolis flowmeter
Operating Instruction (BA) -
Proline Promass A 500
Modbus RS485
Coriolis flowmeter
Operating Instruction (BA) -
Proline Promass A 500
PROFIBUS DP
Coriolis flowmeter
Operating Instruction (BA) -
Proline Promass A 500
EtherNet/IP
Coriolis flowmeter
Operating Instruction (BA) -
Proline Promass A 500
PROFIBUS PA
Coriolis flowmeter
Operating Instruction (BA) -
Proline Promass A 500
HART
Coriolis flowmeter
Operating Instruction (BA) -
Proline Promass A 500
PROFINET
Coriolis flowmeter
Operating Instruction (BA) -
Proline Promass 500
EtherNet/IP
Description of Device Parameters
Coriolis flowmeter
Device Parameter (GP) -
Proline Promass 500
FOUNDATION Fieldbus
Description of Device Parameters
Coriolis flowmeter
Device Parameter (GP) -
Proline Promass 500
HART
Description of Device Parameters
Coriolis flowmeter
Device Parameter (GP) -
Proline Promass 500
PROFIBUS DP
Description of Device Parameters
Coriolis flowmeter
Proline Promass 500
PROFIBUS DPDevice Parameter (GP) -
Proline Promass 500
PROFINET
Description of Device Parameters
Coriolis flowmeter
Device Parameter (GP) -
Proline Promass 500
PROFIBUS PA
Description of Device Parameters
Coriolis flowmeter
Device Parameter (GP) -
Proline Promass 500
Modbus RS485
Description of Device Parameters
Coriolis flowmeter
Device Parameter (GP) -
Proline 500 – digital
PROFIBUS PA
Brief Operating Instructions
Transmitter with Coriolis sensor
Short Instruction (KA)11/18English -
Proline 500
PROFIBUS PA
Brief Operating Instructions
Transmitter with Coriolis sensor
Short Instruction (KA)11/18English -
Proline 500
HART
Brief Operating Instructions
Transmitter with Coriolis sensor
Short Instruction (KA)08/18English -
Proline 500 – digital
EtherNet/IP
Brief Operating Instructions
Transmitter with Coriolis sensor
Short Instruction (KA)08/18English -
Proline 500
Modbus RS485
Brief Operating Instructions
Transmitter with Coriolis sensor
Short Instruction (KA)08/18English -
Proline 500
EtherNet/IP
Brief Operating Instructions
Transmitter with Coriolis sensor
Short Instruction (KA)08/18English -
Proline 500 – digital
Modbus RS485
Brief Operating Instructions
Transmitter with Coriolis sensor
Short Instruction (KA)08/18English -
Proline 500 – digital
HART
Brief Operating Instructions
Transmitter with Coriolis sensor
Short Instruction (KA)08/18English -
Proline 500
FOUNDATION Fieldbus
Brief Operating Instructions
Transmitter with Coriolis sensor
Short Instruction (KA)08/18English -
Proline 500 – digital
FOUNDATION Fieldbus
Brief Operating Instructions
Transmitter with Coriolis sensor
Short Instruction (KA)08/18English -
Proline 500 – digital
PROFINET
Brief Operating Instructions
Transmitter with Coriolis sensor
Short Instruction (KA)08/18English -
Proline 500
PROFINET
Brief Operating Instructions
Transmitter with Coriolis sensor
Short Instruction (KA)08/18English -
Proline 500 – digital
PROFIBUS DP
Brief Operating Instructions
Transmitter with Coriolis sensor
Short Instruction (KA)06/18English -
Proline 500
PROFIBUS DP
Brief Operating Instructions
Transmitter with Coriolis sensor
Short Instruction (KA)06/18English -
Flowmeter
Proline Promass A
Brief Operating Instructions
Proline Promass A
Coriolis sensorShort Instruction (KA)03/19English -
Weather Protection
Promag, Promass 300, 500, Prosonic Flow, t-mass 300
Installation Instructions (EA) -
Protective Cover connection compartment
Promag, Promass 300, 500, 500-digital, Prosonic Flow, t-mass 300,
500-digitalInstallation Instructions (EA) -
Replacing cover, O-ring cover, Interface gasket
Promag, Promass 300, 500, Prosonic Flow, t-mass 300
Installation Instructions (EA) -
Replacing the Sensor
Promag, Promass, Prosonic Flow 500-digital
Installation Instructions (EA) -
Replacing cover, O-ring, seal housing for transmitter wall mounting and
seal housing for the sensor side
Promag, Promass 500, 500-digital, Prosonic Flow, t-mass 500-digital
Installation Instructions (EA) -
Replacing the Components for the Transmitter
Promag 400 Index C, Promag, Promass, Prosonic Flow, t-mass 500-digital
Installation Instructions (EA) -
Replacing the terminal connection
Promag, Promass 300, 500, 500-digital, Prosonic Flow, t-mass 300,
500-digitalInstallation Instructions (EA) -
Replacement of parts for the sensor connection housing, remote version
Promag 400 Index C, Promag 500, Promag, Promass, Prosonic Flow, t-mass
500-digitalInstallation Instructions (EA) -
Sensor holder set
Installation Instructions
Promass A 200, Promass A 300, Promass A 500, Promass A 500-digital
Installation Instructions (EA) -
Replacing the S-DAT
Installation Instructions
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital,
t-mass 300, 500-digitalInstallation Instructions (EA) -
Replacing ISEM electronics module, ISEM extender, ribbon cable
Promag, Promass 300, 500, 500-digital, Prosonic Flow, t-mass 300,
500-digitalInstallation Instructions (EA) -
Replacing connection board
Installation Instructions
Promag, Promass 500
Installation Instructions (EA) -
Replacing Small Parts
Promag 400 , Promag 800 Index B, Cubemass, Promag 500, Promag, Promass,
Prosonic Flow, t-mass 500-digitalInstallation Instructions (EA) -
Replacing the display module
Promag, Promass 300, 500, 500-digital, Prosonic Flow, t-mass 300,
500-digital, DKX001–Installation Instructions (EA) -
Replacing the electronics
Promag, Promass 300, 500, 500-digital, Prosonic Flow, t-mass 300,
500-digitalInstallation Instructions (EA) -
Replacing the Display Protection
Promag 400 Index C, Promag, Promass, Prosonic Flow, t-mass 500-digital
Installation Instructions (EA) -
Replacing RJ45-M12 Adapter
Proline 300, 500-digital
Installation Instructions (EA) -
Replacing Spare Parts
Promag, Promass 100, CNG-, LNG-, LPGmass, Promag 400 Index C, Proline
300, 500, 500-digital, Prosonic Flow E 100, Prosonic Flow E He
at, Prosonic Flow, t-mass 300, 500-digitalInstallation Instructions (EA) -
Weather Protection
Promag, Promass, Prosonic Flow, t-mass 500-digital
Installation Instructions (EA) -
Replacing Small parts
Promag, Promass 100, 500, CNG-, LNG-, LPGmass, Promag 400 Index C,
Prosonic Flow E 100, Prosonic Flow E Heat, Prosonic Flow, t-mass
500-digitalInstallation Instructions (EA) -
Alteration with correspondent I/O hardware for HART, Modbus
Promag, Promass 300, 500, 500-digital
Installation Instructions (EA) -
Proline Promass 500
ATEX:
II2G, II1/2G
II2D
IECEx:
Zone 1, Zone 0/1
Zone 21Ex Safety Instructions (XA) -
Proline Promass 500
ATEX:
II3G
IECEx:
Zone 2Ex Safety Instructions (XA) -
Proline Promass 500
Class I Zone 2
Class I Division 2Ex Safety Instructions (XA) -
Proline Promass 500
Class I, Division 1 for IS
(Ex i Intrinsically safe version)Ex Safety Instructions (XA) -
Proline Promass 500
INMETRO:
Zone 2Ex Safety Instructions (XA) -
Proline Promass 500
INMETRO:
Zone 0/1
Zone 1
Zone 2
Zone 21Ex Safety Instructions (XA) -
Proline Promass 500
Class I, Zone 1
Zone 21Ex Safety Instructions (XA) -
Proline Promass 500
NEPSI:
Zone 2Ex Safety Instructions (XA) -
Proline Promass 500
JPN:
Zone 1
Zone 0/1
Zone 21Ex Safety Instructions (XA) -
Proline Promass 500
NEPSI:
Zone 0/1
Zone 1
Zone 21Ex Safety Instructions (XA) -
Proline Promass 500
HART
Concentration Measurement application package
Special Documentation
Coriolis flowmeter
Concentration Measurement application packageSpecial Documentation (SD) -
Proline Promass 500
EtherNet/IP
Heartbeat Verification + Monitoring application package
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Proline Promass 500
HART
Heartbeat Verification + Monitoring application package
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Proline Promass 500
PROFIBUS DP
Web server
Special Documentation
Web server
Special Documentation (SD) -
Heating jacket
For Promass A Coriolis flowmeters
Special Documentation
Heating jacket
For Promass A Coriolis flowmetersSpecial Documentation (SD) -
Proline Promass 500
Modbus RS485
Concentration Measurement application package
Special Documentation
Coriolis flowmeter
Concentration Measurement application packageSpecial Documentation (SD) -
Proline Promass 500
PROFIBUS DP
Concentration Measurement application package
Special Documentation
Coriolis flowmeter
Concentration Measurement application packageSpecial Documentation (SD) -
Proline Promass 300 and 500
HART, MODBUS and PROFINET
Gas Fraction HandlerSpecial Documentation (SD) -
Proline Promass 500
PROFINET
Heartbeat Verification + Monitoring application package
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Proline Promass 500
PROFIBUS PA
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promass 500
FOUNDATION Fieldbus
Concentration Measurement application package
Special Documentation
Coriolis flowmeter
Concentration Measurement application packageSpecial Documentation (SD) -
Proline Promass 500
Functional Safety Manual
Special Documentation (SD) -
Proline Promass 500
Modbus RS485
Heartbeat Verification + Monitoring application package
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Proline Promag/Promass
EtherNet/IP
System integration
Special Documentation (SD) -
Display modules A309/A310
Display with WLAN interface
Special Documentation (SD) -
Proline Promass 500
PROFIBUS PA
Heartbeat Verification + Monitoring application package
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Proline Promass 500
PROFIBUS PA
Concentration Measurement application package
Special Documentation
Coriolis flowmeter
Concentration Measurement application packageSpecial Documentation (SD) -
Proline Promass 500
FOUNDATION Fieldbus
Heartbeat Verification + Monitoring application package
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Proline Promass 500
EtherNet/IP
Concentration Measurement application package
Special Documentation
Coriolis flowmeter
Concentration Measurement application packageSpecial Documentation (SD) -
Proline Promass 500
PROFINET
Concentration Measurement application package
Special Documentation
Coriolis flowmeter
Concentration Measurement application packageSpecial Documentation (SD) -
Proline Promass 500
PROFIBUS DP
Heartbeat Verification + Monitoring application package
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Proline Promass 300/500
Manufacturer information regarding firmware update (NE 53)
New Firmware version:
Promass 300/500 Modbus RS485 : 1.05.00Manufacturer Information (MI) -
Proline Promass 300/500
Manufacturer information regarding firmware update (NE 53)
New Firmware version:
Promass 300/500 PROFINET: 1.01.00Manufacturer Information (MI) -
Proline Promass 300 500
Manufacturer information regarding firmware update (NE 53)
New Firmware version:
Promass 300 500 HART: 1.05.00Manufacturer Information (MI) -
Proline Promass A – Le champion de la performance pour les débits les
plus faibles
(eBook – PC version)
Dans de nombreuses applications des industries du process, de
l'agroalimentaire et des sciences de la vie, il est nécessaire de
mesurer de toutes
petites quantités d'une substance avec une très grande précision, par
ex. des arômes, des
principes actifs ou encore des substances inhibitrices de corrosion.Competence Brochure (CP)08/18fr -
Proline Promass A – The lightweight champion with the highest
accuracy for the lowest flow rates (e-book – PC version)
eBook: Check out this compact Coriolis single-tube system for the
precise measurement of the lowest flow quantities of just a few grams
per minute, and easily access related tools such as movies, brochures,
etc.Competence Brochure (CP)08/18English -
Proline Promass A – The lightweight champion with the highest
accuracy for the lowest flow rates (e-book – Tablet version)
eBook: Check out this compact Coriolis single-tube system for the
precise measurement of the lowest flow quantities of just a fewgrams per
minute, and easily access related tools such as movies, brochures, etc.Competence Brochure (CP)08/18English -
Proline Promass A – Le champion de la performance pour les débits les
plus faibles
(eBook – Tablet version)
Dans de nombreuses applications des industries du process, de
l'agroalimentaire
et des sciences de la vie, il est nécessaire de mesurer de toutes
petites quantités
d'une substance avec une très grande précision, par ex. des arômes, des
principes actifs
ou encore des substances inhibitrices de corrosion.Competence Brochure (CP)08/18fr -
Proline Promass A
Le champion de la performance pour les débits les plus faibles
Innovations (IN)06/18fr -
Proline Promass A
Der Leichtgewichts-Champion mit höchster Genauigkeit
für kleinste DurchflüsseInnovations (IN)06/18German -
Proline Promass A
The lightweight champion with the highest accuracy
for the lowest flow ratesInnovations (IN)06/18English -
Proline 300/500
The future-oriented flow measuring technology
Innovations (IN)03/18English -
流量計 Proline 300/500
未来志向の流量測定技術
Innovations (IN)03/18Japanese -
Proline 300/500
Die zukunftsweisende Durchfluss-Messtechnik
Innovations (IN)03/18German -
Promass A500
Massedurchflussmesser getrennte Bauform zur direkten Erfassung des
Massendurchflusses, der Messstoffdichte und der Temperatur nachdem
Coriolis-PrinzipTender Text04/20German -
GSD Single, GSD_EH_PA_FL_Promass300_500_0x156D_0x01_0x01, 03.08.2016 (Flow, Promass 300 500, 0x156D)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_PA_FL_Promass300500_0x156D_0x02, 12.11.2018 (Flow, Promass 300 500, 0x156D)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_PN_FL_Promass300500_0x843B_0x02, 10.09.2019 (Flow, Promass 300 500, 0x843B)
PROFINET,
PROFINET System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_DP_FL_Promass_300500_0x156F_0x01_0x01, 04.06.2018 (Flow, Promass 300 500, 0x156F)
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_PN_FL_Promass300500_0x843B_0x01_0x01, 16.11.2017 (Flow, Promass 300 500, 0x843B)
PROFINET,
PROFINET System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDS Single, EDS_EIP_FL_Promass_300500_0x103B_0x01_0x01, 07.01.2020 (Flow, Promass 300 500, 0x103B)
EtherNet/IP,
EtherNet IP System Version: AnyElectronic Data Sheet (EDS)1.3Language neutral -
EDD Single, AMS12_HART_FL_Promass300_500_0x113B_0x02_0x01, 22.11.2018 (Flow, Promass 300 500, 0x113
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5, 14.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Promass300_500_0x113B_0x02_0x01, 22.11.2018 (Flow, Promass 300 500, 0x113
HART,
AMS Version: 11.0, 11.1, 11.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS13_FF_FL_Promass_300500_0x103B_0x01_0x01, 15.03.2017 (Flow, Promass 300 500, 0x103B)
FOUNDATION Fieldbus H1,
AMS Version: 13.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promass300_500_0x113B_0x02_0x01, 28.11.2017 (Flow, Promass 300 500, 0x113B)
HART,
Experion Version: R432.1
Field Device Manager Version: R450.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promass300_500_0x113B_0x06_0x01, 28.10.2019 (Flow, Promass 300 500, 0x113B)
HART,
Experion Version: R500
Field Device Manager Version: R500Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Promass300_500_0x113B_0x06_0x01, 25.09.2020 (Flow, Promass 300 500, 0x113
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5, 14.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Promass300_500_0x113B_0x06_0x01, 25.09.2020 (Flow, Promass 300 500, 0x113
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promass300_500_0x113B_0x06_0x01, 20.11.2019 (Flow, Promass 300 500, 0x113B)
HART,
PDM Version: 8.2.1, 9.1.0.4Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PN_FL_Promass300_500_0x843B_0x01_0x01, 27.11.2017 (Flow, Promass 300 500, 0x843B)
PROFINET,
PDM Version: 8.2.1, 9.0.1.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_FF_FL_Promass_300500_0x103B_0x01_0x01, 15.03.2017 (Flow, Promass 300 500, 0x103B)
FOUNDATION Fieldbus H1,
AMS Version: 11.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promass300_500_0x113B_0x02_0x01, 27.11.2017 (Flow, Promass 300 500, 0x113B)
HART,
PDM Version: 8.2.1, 9.0.1.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_FL_Promass300_500_0x156D_0x01_0x01, 03.08.2016 (Flow, Promass 300 500, 0x156D)
PROFIBUS PA,
PDM Version: 6.1, 8.2.1, 9.0, 9.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PN_FL_Promass300_500_0x843B_0x02_0x01, 20.09.2019 (Flow, Promass 300 500, 0x843B)
PROFINET,
PDM Version: 8.2.1, 9.1.0.4Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_FL_Promass300500_0x156D_0x02_0x01, 18.01.2019 (Flow, Promass 300 500, 0x156D)
PROFIBUS PA,
PDM Version: 8.1, 9.1.0.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_DP_FL_Promas300500_0x156F_0x01_0x01, 16.07.2018 (Flow, Promass 300 500, 0x156F)
PROFIBUS DP,
PDM Version: 8.2.1, 9.1.0.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_FF_FL_Promass_300500_0x103B_0x01_0x01, 15.03.2017 (Flow, Promass 300 500, 0x103B)
FOUNDATION Fieldbus H1,
AMS Version: 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EDD_FF_FL_Promass300500_0x103B_0x01_0x01, 29.09.2017 (Flow, Promass 300 500, 0x103B)
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: AnyElectronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_FF_FL_Promass_300500_0x103B_0x01_0x01, 17.03.2017 (Flow, Promass 300 500, 0x103B)
FOUNDATION Fieldbus H1,
AMS Version: 10.0Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, Promass_300_500_0x103B_FF_FW1_00_zz_Dev_Rev_01, 22.10.2020 (Flow, Promass 300 500, 0x10
FOUNDATION Fieldbus H1,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.07.00
Field Device Manager Version: R450.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 4.1
Plant Resource Manager Version: R3.20Device Type Manager (DTM)1.9.0.197Language neutral -
DTM Single, Promass_300_500_8x3x_8x5x_FW_1_00_zz_Dev_Rev_1, 21.10.2020 (Flow, Promass 300 500, 0x15
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.8.0.128Language neutral -
DTM Single, Promass_300_500_HART_FW_1_05_zz_Dev_Rev_06, 27.10.2020 (Flow, Promass 300 500, 0x113B)
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.07.00
Field Device Manager Version: R500
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 5.0
Plant Resource Manager Version: R3.31Device Type Manager (DTM)1.39.0.646Language neutral -
DTM Single, Promass_300_500_MR4_FW_1_05_00_Dev_Rev_06, 06.11.2020 (Flow, Promass 300 500, 0x643B)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.39.0.289Language neutral -
DTM Single, Promass_300_500_MR4-CDIE_FW_1_05_zz_Dev_Rev_06, 06.11.2020 (Flow, Promass 300 500, 0x64
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.39.0.289Language neutral -
DTM Single, Promass300500_PN-CDIE_FW_1_01_zz_Dev_Rev_02, 05.11.2020 (Flow, Promass 300 500, 0x843B)
PROFINET,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.39.0.222Language neutral -
DTM Single, Promass_300_500_8x3x-8x5x_FW_1_01_zz_Dev_Rev_02, 21.10.2020 (Flow, Promass 300 500, 0x1
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 5.0Device Type Manager (DTM)1.12.0.193Language neutral -
DTM Single, Promass_300_500_DP_FW_1_00_zz_Dev_Rev_01, 19.10.2020 (Flow, Promass 300 500, 0x156F)
PROFIBUS DP,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 5.0Device Type Manager (DTM)1.11.0.93Language neutral -
DTM Single, Promass_300_500_EIP-CDIE_FW_1_00_zz_Dev_Rev_01, 05.11.2020 (Flow, Promass 300 500, 0x10
EtherNet/IP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.10.0.94Language neutral -
DTM Single, Promass_300_500_EIP_FW_1_00_zz_Dev_Rev_01, 05.11.2020 (Flow, Promass 300 500, 0x103B)
EtherNet/IP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
Unity Pro XL Version: 12.0Device Type Manager (DTM)1.10.0.94Language neutral -
DTM Single, Promass_300_500_HART_FW_1_01_zz_Dev_Rev_02, 27.10.2020 (Flow, Promass 300 500, 0x113B)
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.07.00
Field Device Manager Version: R450.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 5.0
Plant Resource Manager Version: R3.31Device Type Manager (DTM)1.10.0.441Language neutral -
DTM Single, Promass_300_500_MR4-CDIE_FW_1_01_zz_Dev_Rev_2, 06.11.2020 (Flow, Promass 300 500, 0x643
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.10.0.237Language neutral -
DTM Single, Promass_300_500_MR4_FW_1_01_zz_Dev_Rev_02, 06.11.2020 (Flow, Promass 300 500, 0x643B)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.10.0.237Language neutral -
DTM Single, Promass300500_PN-CDIE_FW_1_00_zz_Dev_Rev_01, 05.11.2020 (Flow, Promass 300 500, 0x843B)
PROFINET,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.10.0.115Language neutral -
AOP Single, RS_EIP_FL_Promass300500_0x103B_0x01_0x01, 10.02.2021 (Flow, Promass 300 500, 0x103B)
EtherNet/IP,
RA RSLogix 5000 Version: V15 and laterAdd On Profile (AOP)1.66.01Language neutral -
AOP Single, RS_EIP_FL_Promass300500_0x103B_0x01_0x01_AOP, 28.08.2019 (Flow, Promass 300 500, 0x103B)
EtherNet/IP,
RA RSLogix 5000 Version: V20.04and later
RA Studio 5000 Version: V21 and laterAdd On Profile (AOP)1.19Language neutral -
Faceplate Single, PRM_FF_FL_Promass_300500_0x103B_0x01_0x01, 15.03.2017 (Flow, Promass 300 500, 0x1
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.20Faceplate1.00.00Language neutral -
Faceplate Single, PRM_HART_FL_Promass300_500_0x113B_0x06_0x01, 28.10.2019 (Flow, Promass 300 500, 0
HART,
Plant Resource Manager Version: R3.31Faceplate1.00.00Language neutral -
Faceplate Single, PRM_HART_FL_Promass300_500_0x113B_0x02_0x01, 28.11.2017 (Flow, Promass 300 500, 0
HART,
Plant Resource Manager Version: R3.31Faceplate1.00.00Language neutral -
Verification DTM Library, VerificationDTM_FLOW_Modbus_RS485, 15.05.2020 (Flow)
Modbus RS485,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_ProfiNet, 15.05.2020 (Flow)
PROFINET,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_HART, 15.05.2020 (Flow)
HART,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_PROFIBUS_DP, 15.05.2020 (Flow)
PROFIBUS DP,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_PROFIBUS_PA, 15.05.2020 (Flow)
PROFIBUS PA,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_FOUNDATION_Fieldbus, 15.05.2020 (Flow)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_EIP, 15.05.2020 (Flow)
EtherNet/IP,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Proline Promass A Virtual Reality Animation
Empfehlung: Nutzung nur in Verbindung mit gebräuchlicher VR Brille
Animation08/18German -
Proline Promass A virtual reality animation
Use in combination with VR glasses only
Animation08/18English -
Dosimass OEM, Promass 40, Promass 80, Promass 83, Promass 84, Promass A, Promass E, Promass F, Promass Q
Product Code: 8E3B-, 8E5B-, 8F1B-, 8F2B-, 8F3B-, 8F5B-, 8PE-, 8Q3B-, 8Q5B-, 8RE-, O8E1B-, O8E1C-, O8E3B-, O8E5B-, O8F1B-, O8F3B-, O8F5B-, O8Q3B-, O8Q5B-, 8E2B-, 8E1C-, 8E1B-, 8BE-, 8A5C-, 8A5B-, 8A3C-, 8A3B-, 8A2B-, 8A1B-, 84F-, 84A-, 83F-, 83E-, 83A-, 80F-, 80E-, 80A-, 40E-
Declaration Number: HE_00351_04.16
Manufacturer Specification: Food hygiene, 1935/2004Manufacturer DeclarationEnglish -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A
Product Code: 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8A5C-, 8A5B-, 8A3C-, 8A3B-
Declaration Number: EC_00405_07.16EU DeclarationGerman , English -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A
Product Code: 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8A5C-, 8A5B-, 8A3C-, 8A3B-
Declaration Number: EC_00406_04.16EU DeclarationGerman , English -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A
Product Code: 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8A5C-, 8A5B-, 8A3C-, 8A3B-
Declaration Number: EC_00424_05.16EU DeclarationGerman , English -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass K, Promass I, Promass H, Promass G, Promass F, Promass E, Promass A, Promass 84, Promass 83, Promass 80, Promass 40, LPGmass, CNGmass
Product Code: 8O1B-, 8K1B-, 8I5B-, 8I3B-, 8I1B-, 8H5B-, 8H3B-, 8H1B-, 8G1B-, 8FF-, 8FE-, 8F5B-, 8F3B-, 8F1B-, 8O3B-, 8O5B-, 8P1B-, 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S1B-, 8S1C-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, D8CB-, 40E-, 80A-, 80E-, 80F-, 80H-, 80I-, 80P-, 80S-, 83A-, 83E-, 83F-, 83H-, 83I-, 83P-, 83S-, 83X-, 84A-, 84F-, 84X-, 8A1B-, 8A3B-, 8A3C-, 8A5B-, 8A5C-, 8DF-, 8E1B-, 8E3B-, 8E5B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.02228/20MiscellaneousRussian -
Promass X, Promass F, Promass E, Promass 83, Promass P, Promass S, Promass I, Promass O, Promass H, Promass A, Promass 84, Promass 80, Promass 40
Product Code: 8E1B-, 83F-, 83E-, 83H-, 83I-, 83P-, 83M-, 83S-, 83A-, 8F2B-, 8F1B-, 8I1B-, 8S1B-, 83O-, 83X-, 8A1B-, 80F-, 80E-, 80H-, 8E2B-, 80I-, 84F-, 80P-, 80S-, 8O1B-, 80A-, 8P5B-, 8I5B-, 8H5B-, 8S5B-, 8F5B-, 8F3B-, 8E3B-, 8E5B-, 8S3B-, 8I3B-, 8O3B-, 8P3B-, 8H3B-, 8X3B-, 84A-, 8A5B-, 8A3B-, 40E-, 8X5B-, 8S1C-, 8E2C-, 84X-, 8A5C-, 8A3C-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC RU D-CH.MU62.B.02333MiscellaneousRussian -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Cubemass C
Product Code: 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8C5B-, 8C3B-, 8A5C-, 8A5B-, 8A3C-, 8A3B-
Region/Country: USA, Canada
Approval Agency: CSA
Category: I/2/A,B,C,D T6...T1, I/2/A,B,C,D A,B,C,D, I/2/A,B,C,DExplosion ProtectionEnglish -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Product Code: O8X5B-, O8Q5B-, O8O5B-, O8F5B-, O8E5B-, 8X5B-, 8S5B-, 8Q5B-, 8P5B-, 8O5B-, 8I5B-, 8H5B-, 8F5B-, 8E5B-, 8C5B-, 8A5C-, 8A5B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 2Explosion ProtectionChinese -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Product Code: O8X5B-, O8Q5B-, O8O5B-, O8F5B-, O8E5B-, 8X5B-, 8S5B-, 8Q5B-, 8P5B-, 8O5B-, 8I5B-, 8H5B-, 8F5B-, 8E5B-, 8C5B-, 8A5C-, 8A5B-
Region/Country: Japan
Approval Agency: CMLExplosion ProtectionJapanese -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Cubemass C
Product Code: 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8C5B-, 8C3B-, 8A5C-, 8A5B-, 8A3C-, 8A3B-
Region/Country: USA, Canada
Approval Agency: CSA
Category: I,II,III/1/A,B,C,D,E,F,G T6...T1, I,II,III/1/A,B,C,D,E,F,G A,B,C,D,E,F,G, I,II,III/1/C,D,E,F,G T6...T1, I,II,III/1/C,D,E,F,G C,D,E,F,GExplosion ProtectionEnglish -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Product Code: O8X5B-, O8Q5B-, O8O5B-, O8F5B-, O8E5B-, 8X5B-, 8S5B-, 8Q5B-, 8P5B-, 8O5B-, 8I5B-, 8H5B-, 8F5B-, 8E5B-, 8C5B-, 8A5C-, 8A5B-
Region/Country: Europe (ATEX)
Approval Agency: SIRA
Protection: [Ex ia], Ex ia, Ex tb, Ex db eb ia, Ex eb ia, Ex dbExplosion ProtectionEnglish -
Promass A, Promass F, Promass E, Promass P, Promass I, Promass S, Promass H, Promass O, Promass Q, Promass X
Product Code: 8Q5B-, 8P5B-, 8I5B-, 8S5B-, 8O5B-, 8H5B-, 8F5B-, 8F3B-, 8S3B-, 8E5B-, 8E3B-, 8P3B-, 8O3B-, 8I3B-, 8H3B-, 8Q3B-, 8X3B-, 8A5B-, 8A3B-, 8X5B-, O8E3B-, O8E5B-, O8F3B-, O8F5B-, O8O3B-, O8O5B-, O8Q3B-, O8Q5B-, O8X3B-, O8X5B-, 8A3C-, 8A5C-
Region/Country: Russia, Russia (TR CU)
Approval Agency: EAC
Protection: Ex tb [ia Da] IIIC Txxx°C Db, Ex nA [ia Ga] IIC T5 Gc, Ex d e [ia Ga] IIC IIC Gb, Ex d e [ia Ga] IIB IIB Gb, Ex d [ia Ga] IIC T6...T1 Gb, Ex d [ia Ga] IIC T6...T1 Ga/Gb, Ex tb IIIC Txxx°C Db, Ex nA IIIC IIIC Gc, Ex nA IIC T6...T1 Gc, Ex ia IIC T6...T1 Gb, Ex ia IIC T6...T1 Ga/Gb, Ex ia IIB T6...T1 Gb, Ex ia IIB T6...T1 Ga/Gb, Ex d IIC T6...T1 Gb, Ex d IIC T6...T1 Ga/Gb, [Ex ia] IIIC, [Ex ia] IICExplosion ProtectionRussian -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Product Code: 8P5B-, 8Q3B-, 8Q5B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, O8E3B-, O8E5B-, O8F3B-, O8F5B-, O8O3B-, O8O5B-, O8Q3B-, O8Q5B-, O8X3B-, O8X5B-, 8A3B-, 8A3C-, 8A5B-, 8A5C-, 8C3B-, 8C5B-, 8E3B-, 8E5B-, 8F3B-, 8F5B-, 8H3B-, 8H5B-, 8I3B-, 8I5B-, 8O3B-, 8O5B-, 8P3B-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/1/A,B,C,D,E,F,G, I/1/A,B,C,D, I/1/C,D,E,F,GExplosion ProtectionEnglish -
Promass A
Product Code: 8A5C-
Region/Country: South Korea
Approval Agency: KTL
Category: zone 1, zone 21
Protection: Ex d [ia] IIC T6...T4Explosion Protection -
Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Product Code: 8Q3B-, 8Q5B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, O8E3B-, O8E5B-, O8F3B-, O8F5B-, O8O3B-, O8O5B-, O8Q3B-, O8Q5B-, O8X3B-, O8X5B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8A5C-, 8A5B-, 8A3C-, 8A3B-
Region/Country: Russia (TR CU), Russia
Approval Agency: EAC
Protection: Ex tb [ia Da] IIIC Txxx°C Db, Ex nA [ia Ga] IIC T5 Gc, Ex d e [ia Ga] IIC IIC Gb, Ex d e [ia Ga] IIB IIB Gb, Ex d [ia Ga] IIC T6...T1 Gb, Ex d [ia Ga] IIC T6...T1 Ga/Gb, Ex tb IIIC Txxx°C Db, Ex nA IIIC IIIC Gc, Ex nA IIC T6...T1 Gc, Ex ia IIC T6...T1 Gb, Ex ia IIC T6...T1 Ga/Gb, Ex ia IIB T6...T1 Gb, Ex ia IIB T6...T1 Ga/Gb, Ex d IIC T6...T1 Gb, Ex d IIC T6...T1 Ga/Gb, [Ex ia] IIIC, [Ex ia] IICExplosion ProtectionRussian -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Promag W, Promag P, Promag H
Product Code: 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, O5W3B-, O8E3B-, O8E5B-, O8F3B-, O8F5B-, O8O3B-, O8O5B-, O8Q3B-, O8Q5B-, O8X3B-, O8X5B-, 8O5B-, 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-, 8A3B-, 8A3C-, 8A5B-, 8A5C-, 8E3B-, 8E5B-, 8F3B-, 8F5B-, 8H3B-, 8H5B-, 8I3B-, 8I5B-, 8O3B-
Region/Country: Ukrain
Approval Agency: DVSZVE
Category: zone 1, zone 21Explosion Protection -
Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Product Code: O8X5B-, O8Q5B-, O8O5B-, O8F5B-, O8E5B-, 8X5B-, 8S5B-, 8Q5B-, 8P5B-, 8O5B-, 8I5B-, 8H5B-, 8F5B-, 8E5B-, 8A5C-, 8A5B-
Region/Country: Brazil
Approval Agency: TÜV
Category: zone 1, zone 21, zone 0,1
Protection: Ex ia, Ex tb, Ex db eb, Ex dbExplosion ProtectionPortuguese -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Product Code: O8X5B-, O8Q5B-, O8O5B-, O8F5B-, O8E5B-, 8X5B-, 8S5B-, 8Q5B-, 8P5B-, 8O5B-, 8I5B-, 8H5B-, 8F5B-, 8E5B-, 8C5B-, 8A5C-, 8A5B-
Region/Country: Japan
Approval Agency: CMLExplosion ProtectionJapanese -
Promass A
Product Code: 8A5C-
Region/Country: South Korea
Approval Agency: KTL
Category: zone 1, zone 2
Protection: Ex ia IIC T6...T1Explosion Protection -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Product Code: O8X5B-, O8Q5B-, O8O5B-, O8F5B-, O8E5B-, 8X5B-, 8S5B-, 8Q5B-, 8P5B-, 8O5B-, 8I5B-, 8H5B-, 8F5B-, 8E5B-, 8C5B-, 8A5C-, 8A5B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 21, zone 0,1Explosion ProtectionChinese -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Product Code: 8P5B-, 8Q3B-, 8Q5B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, O8E3B-, O8E5B-, O8F3B-, O8F5B-, O8O3B-, O8O5B-, O8Q3B-, O8Q5B-, O8X3B-, O8X5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8C5B-, 8C3B-, 8A5C-, 8A5B-, 8A3C-, 8A3B-
Region/Country: India
Approval Agency: CC(O)E
Category: zone 1,2Explosion ProtectionEnglish -
Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Product Code: O8X5B-, O8Q5B-, O8O5B-, O8F5B-, O8E5B-, 8X5B-, 8S5B-, 8Q5B-, 8P5B-, 8O5B-, 8I5B-, 8H5B-, 8F5B-, 8E5B-, 8A5C-, 8A5B-
Region/Country: Brazil
Approval Agency: TÜV
Category: zone 2
Protection: Ex ecExplosion ProtectionPortuguese -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Product Code: 8P5B-, 8Q3B-, 8Q5B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, O8E3B-, O8E5B-, O8F3B-, O8F5B-, O8O3B-, O8O5B-, O8Q3B-, O8Q5B-, O8X3B-, O8X5B-, 8A3B-, 8A3C-, 8A5B-, 8A5C-, 8C3B-, 8C5B-, 8E3B-, 8E5B-, 8F3B-, 8F5B-, 8H3B-, 8H5B-, 8I3B-, 8I5B-, 8O3B-, 8O5B-, 8P3B-
Region/Country: USA, Canada
Approval Agency: CSA
Category: I/2/A,B,C,DExplosion ProtectionEnglish -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Product Code: 8P5B-, 8Q3B-, 8Q5B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, O8E3B-, O8E5B-, O8F3B-, O8F5B-, O8O3B-, O8O5B-, O8Q3B-, O8Q5B-, O8X3B-, O8X5B-, 8A3B-, 8A3C-, 8A5B-, 8A5C-, 8C3B-, 8C5B-, 8E3B-, 8E5B-, 8F3B-, 8F5B-, 8H3B-, 8H5B-, 8I3B-, 8I5B-, 8O3B-, 8O5B-, 8P3B-
Region/Country: USA, Canada
Approval Agency: CSA
Category: I/2/A,B,C,DExplosion ProtectionEnglish -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Product Code: O8X5B-, O8Q5B-, O8O5B-, O8F5B-, O8E5B-, 8X5B-, 8S5B-, 8Q5B-, 8P5B-, 8O5B-, 8I5B-, 8H5B-, 8F5B-, 8E5B-, 8C5B-, 8A5C-, 8A5B-
Region/Country: International (IECEx)
Approval Agency: CSA
Protection: [Ex ia], Ex ia, Ex tb, Ex db eb, Ex dbExplosion ProtectionEnglish -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Product Code: 8P5B-, 8Q3B-, 8Q5B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, O8E3B-, O8E5B-, O8F3B-, O8F5B-, O8O3B-, O8O5B-, O8Q3B-, O8Q5B-, O8X3B-, O8X5B-, 8A3B-, 8A3C-, 8A5B-, 8A5C-, 8C3B-, 8C5B-, 8E3B-, 8E5B-, 8F3B-, 8F5B-, 8H3B-, 8H5B-, 8I3B-, 8I5B-, 8O3B-, 8O5B-, 8P3B-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/1/A,B,C,D,E,F,G, I/1/A,B,C,D, I/1/C,D,E,F,GExplosion ProtectionEnglish -
Promass A
Product Code: 8A5C-
Region/Country: South Korea
Approval Agency: KTL
Category: zone 1, zone 21
Protection: Ex tb IIIC Txxx°CExplosion Protection -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Product Code: O8X5B-, O8Q5B-, O8O5B-, O8F5B-, O8E5B-, 8X5B-, 8S5B-, 8Q5B-, 8P5B-, 8O5B-, 8I5B-, 8H5B-, 8F5B-, 8E5B-, 8C5B-, 8A5C-, 8A5B-
Region/Country: International (IECEx)
Approval Agency: IECEx
Protection: Ex ecExplosion ProtectionEnglish -
Promass A, Promass E, Promass F, Promass I, Promass P, Promass Q, Promass S
Product Code: 8S5B-, 8S3B-, 8S1C-, 8S1B-, 8Q5B-, 8Q3B-, 8Q1B-, 8P5B-, 8P3B-, 8P1B-, 8I5B-, 8I3B-, 8I1B-, 8F5B-, 8F3B-, 8F1B-, 8E5B-, 8E3B-, 8E1C-, 8E1B-, 8A5C-, 8A5B-, 8A3C-, 8A3B-, 8A1B-
Region/Country: USA
Approval Agency: 3-A Sanitary StandardsHygienic EquipmentEnglish -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Cubemass C
Product Code: 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8C5B-, 8C3B-, 8A5C-, 8A5B-, 8A3C-, 8A3B-
Region/Country: International
Approval Agency: FieldComm Group
Software Version: 01.05.00Fieldbus ConformanceEnglish -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Cubemass C
Product Code: 8A5B-, 8A5C-, 8C5B-, 8E5B-, 8F5B-, 8H5B-, 8I5B-, 8O5B-, 8P5B-, 8Q5B-, 8S5B-, 8X5B-
Region/Country: International
Approval Agency: OPC Foundation
Software Version: 01.01.03Fieldbus ConformanceEnglish -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A
Product Code: 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8A5C-, 8A5B-, 8A3C-, 8A3B-
Region/Country: International
Approval Agency: ODVA
Software Version: 01.00.04Fieldbus ConformanceEnglish -
Promass A, Promass E, Promass F, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Region/Country:
Heartbeat TechnologyGerman , English
Accessories / Spare parts
-
-
Nr 31 Order code 71323007
Kit power supply, 100-230VAC, Ex
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing, electronic compartment.
-
Nr 31 Order code 71323008
Kit power supply, 24VDC, Ex
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing, electronic compartment.
-
Nr 31 Order code 71323009
Kit pow.supply,100-230VAC/24VDC, Non-haz
Usage: Promag/Promass/Prosonic Flow/ t-mass 300/500 digital, Non-haz, Zone 2, transmitter housing, electronic compartment.
-
-
-
Nr 47 Order code 71323012
Kit main elec. extender, 500 dig., Ex
Usage: Promass/t-mass 500 digital, transmitter housing, electronic compartment.
-
Nr 47 Order code 71323013
Kit main elec.extender,500 dig., Non-haz
Usage: Promag/Promass/Prosonic Flow/ t-mass 500 digital, transmitter housing, electronic compartment.
-
-
-
Nr 36 Order code 71323015
Kit ISEM extender, 500 digital, Ex
Usage: Promag/Promass/t-mass 500 digital, Sensor connection housing.
-
-
-
Nr 33 Order code XPD0028-
-
-
-
Nr 39 Order code 71185788
Kit T-DAT, 100/300/400/500/500 digital
Usage: Promag/Promass 100/300/500, 500 digital, Prosonic Flow E 100, Prosonic Flow/t-mass 300, 500 digital, Promag 400(C). (C) = generation index C.
-
-
-
Nr 34 Order code XPD0037-
-
-
-
Nr 37 Order code 71323010
Kit module cartridge, 300/500, Ex
Usage: transmitter housing, electronic compartment. Consists of: module cartridge incl. interconnection board.
-
-
-
Nr 46 Order code 71323005
Kit ISEM ribbon cable, 300/500
Usage: Promag/Promass 300/500, t-mass 300, transmitter housing.
-
Nr 46 Order code 71323006
Kit ISEM ribbon cable, 500 digital
Usage: Promag/Promass/t-mass 500 digital, sensor connection housing.
-
-
-
Nr 35 Order code XPD0038-
-
-
-
Nr 45 Order code 71323075
Kit conn.terminal option A, 300/500, Ex
Usage: transmitter housing Alu/cast, connection compartment. Option A = HART, PROFIBUS PA, FOUNDATION Fieldbus. Consists of: 2x connection terminal 2-Pol., 1x connection terminal 4-Pol.
-
-
-
Nr 50 Order code XPD0031-
-
-
-
Nr 45 Order code 71323076
Kit conn.terminal option B, 300/500, Ex
Usage: transmitter housing Alu/cast, connection compartment. Option B = EtherNet, PROFINET. Consists of: 2x connection terminal 2-Pol.
-
Nr 45 Order code 71327819
Kit conn.terminal option C, 300/500, Ex
Usage: transmitter housing Alu/cast, connection compartment. Option C = PROFIBUS DP, Modbus RS485. Consists of: 2x connection terminal 2-Pol., 1x connection terminal 4-Pol.
-
Nr 45 Order code 71323077
Kit terminal option A, 500 dig., Non-haz
Usage: transmitter housing Alu/polycarbonate, connection compartment. Option A = HART, PROFIBUS PA, FOUNDATION Fieldbus. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol., 1x connection terminal 6-Pol.
-
Nr 45 Order code 71323078
Kit terminal option B, 500 dig., Non-haz
Usage: transmitter housing Alu/polycarbonate, connection compartment. Option B = EtherNet, PROFINET. Consists of: 1x connection terminal 3-Pol., 1x connection terminal 4-Pol., 1x connection terminal 6-Pol.
-
Nr 45 Order code 71327820
Kit terminal option C, 500 dig., Non-haz
Usage: transmitter housing Alu/polycarbonate, connection compartment. Option C = PROFIBUS DP, Modbus RS485. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol., 1x connection terminal 6-Pol.
-
-
-
Nr 44 Order code 71323268
Kit connection board, Promass 500, Ex
Usage: Sensor connection housing. Consists of: connection board, O-Ring 26,00x1,50 HNBR.
-
Nr 44 Order code 71323269
Kit connec.board, Promass 500, Ex, -50oC
Usage: Sensor connection housing. Consists of: connection board, O-Ring 26,00x1,50 FVMQ, -50oC/-58oF.
-
-
-
Nr 20 Order code 71323016
Kit cover, sight glass, Alu,Non-haz/Exde
Usage: Promag/Promass/Prosonic Flow/t-mass 300, transmitter housing Alu, Non-haz. Promag/Promass 300/500, transmitter housing Alu, Ex. Consists of: cover sight glass Alu, O-Ring 110.7x3.53 HNBR.
-
Nr 20 Order code 71323017
Kit cover,glass, Alu, -50oC,Non-haz/Exde
Usage: Promass/Prosonic Flow/t-mass 300, transmitter housing Alu, Non-haz. Promag 500, Promass 300/500, transmitter housing Alu, Ex. Consists of: cover Alu, sight glass, O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
-
Nr 20 Order code 71323020
Kit cover, sight glass, Alu, Exd
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu, Ex. Consists of: cover Alu, sight glass, O-Ring 110.7x3.53 HNBR.
-
Nr 20 Order code 71323021
Kit cover, sight glass, Alu, -50oC, Exd
Usage: Promag 500, Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu, Ex. Consists of: cover Alu, sight glass, O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
-
Nr 20 Order code 71323024
Kit cover, sight glass, cast, Ex
Usage: Promag 500, Promass 300/500, Prosonic Flow 300, transmitter housing cast, Ex. Consists of: cover sight glass cast, O-Ring 110.7x3.53 HNBR.
-
Nr 20 Order code 71323025
Kit cover, sight glass, cast, -50oC, Ex
Usage: Promag 500, Promass 300/500, Prosonic Flow 300, transmitter housing cast, Ex. Consists of: cover sight glass cast, O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 70 Order code 71323026
Kit cover gasket, sight glass/blind
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu/cast. Consists of: 10x O-Ring 110.7x3.53 HNBR.
-
Nr 70 Order code 71323027
Kit cover gasket,sight glass/blind,-50oC
Usage: Promag 500, Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu/cast, Consists of: O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 22 Order code 71323032
Kit cover, electronic compart., Alu, Ex
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 120,2x3,53 HNBR.
-
Nr 22 Order code 71323033
Kit cover, electr.compart., Alu,-50oC,Ex
Usage: Promag 500, Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 120,2x3,53 FVMQ, -50oC/-58oF.
-
Nr 22 Order code 71323034
Kit cover, electronic compart., cast, Ex
Usage: Promag 500, Promass 300/500, Prosonic Flow 300, transmitter housing cast, Ex. Consists of: cover cast, O-Ring 120,2x3,53 HNBR.
-
Nr 22 Order code 71323035
Kit cover, electr.compart.,cast,-50oC,Ex
Usage: Promag 500, Promass 300/500, Prosonic Flow 300, transmitter housing cast, Ex. Consists of: cover cast, O-Ring 120,2x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 74 Order code 71323036
Kit cover gasket, electronic compart.,Ex
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu/cast, Ex. Consists of: 10x O-Ring 120,2x3,53 HNBR.
-
Nr 74 Order code 71323037
Kit cover gasket,elect.compart.,-50oC,Ex
Usage: Promag 500, Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu/cast, Ex. Consists of: O-Ring 120,2x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 23 Order code 71323038
Kit cover, wall mount, Alu, Ex
Usage: Promag/Promass 500, wall mount transmitter Alu, Ex, connection compartment. Consists of: cover Alu, O-Ring 88,50x3,53 HNBR.
-
Nr 23 Order code 71323039
Kit cover, wall mount, Alu, -50oC, Ex
Usage: Promag/Promass 500, wall mount transmitter Alu, Ex, connection compartment. Consists of: cover Alu, O-Ring 88,50x3,53 FVMQ, -50oC/-58oF.
-
Nr 23 Order code 71323040
Kit cover, wall mount, cast, Ex
Usage: Promag/Promass 500, wall mount transmitter cast, Ex, connection compartment. Consists of: cover cast, O-Ring 88,50x3,53 HNBR.
-
Nr 23 Order code 71323041
Kit cover, wall mount, cast, -50oC, Ex
Usage: Promag/Promass 500, wall mount transmitter cast, Ex, connection compartment. Consists of: cover cast, O-Ring 88,50x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 75 Order code 71323042
Kit cover gasket, wall mount, Ex
Usage: Promag/Promass 500, wall mount transmitter Alu/cast, Ex, connection compartment. Consists of: 10x O-Ring 88,50x3,53 HNBR.
-
Nr 75 Order code 71323043
Kit cover gasket, wall mount, -50oC, Ex
Usage: Promag/Promass 500, wall mount transmitter Alu/cast, Ex, connection compartment. Consists of: O-Ring 88,50x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 20 Order code 71384170
Kit cover, alu,Promag 400(C),500 digital
Usage: Promag 400(C) = generation index C, Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing Alu. Consists of: cover Alu complete included O-Ring 196,40x3,53 HNBR, default and -50oC/-58oF, wire with screw lock 1,5x150.
-
Nr 20 Order code 71408508
Kit cover, polycarb., 500 digital
Usage: Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing polycarbonate. Consists of: Cover polycarbonate complete, O-Ring 196,44x3,53 VMQ, default and -50oC/-58oF, wire with screw lock 1,5x150.
-
-
-
Nr 70 Order code 71278078
Kit cover gasket, alu,400(C),500 digital
Usage: Promag 400(C) = generation index C, Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing Alu. Consists of: 10x O-Ring 196,40x3,53 HNBR, default and -50oC/-58oF.
-
Nr 70 Order code 71278077
Kit 10 cover gasket, polycarbonate
Usage: Promag 400(C) = generation index C, Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing polycarbonate. Consists of: 10x O-Ring 196,44x3,53 VMQ.
-
-
-
Nr 24 Order code 71228796
Kit cover, remote, Alu
Usage: Promag 400(C) = generation index C, Promag 500, Promag/Promass/Prosonic Flow/t-mass 500 digital, sensor connection housing. Consists of: cover Alu, O-Ring 113,90x3,53 HNBR.
-
Nr 24 Order code 71323050
Kit cover, remote, Alu, -50oC
Usage: Promass/Prosonic Flow/t-mass 500digital, sensor connection housing. Consists of: cover Alu, O-Ring 113,90x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 73 Order code 71323051
Kit housing gaskets, remote, Alu
Usage: Promass/Prosonic Flow/t-mass 500digital, sensor connection housing. Consists of: O-Ring 113,90x3,53 HNBR for cover, gasket EPDM for housing/sensor.
-
Nr 73 Order code 71323052
Kit housing gaskets, remote, Alu, -50oC
Usage: Promass/Prosonic Flow/t-mass 500digital, sensor connection housing. Consists of: O-Ring 113,90x3,53 FVMQ for cover, -50oC/-58oF, gasket FVMQ for housing/sensor, -50oC/-58oF.
-
-
-
Nr 24 Order code 71323053
Kit cover, remote, stainless 1.4301
Usage: Promass 500, Promag/Promass 500 digital, sensor connection housing. Consists of: cover stainless 1.4301, gasket EPDM for cover.
-
Nr 24 Order code 71323054
Kit cover, remote,stainless 1.4301,-50oC
Usage: Promass 500, Promass 500 digital, sensor connection housing. Consists of: cover stainless 1.4301, gasket FVMQ for cover, -50oC/-58oF.
-
-
-
Nr 73 Order code 71323057
Kit housing gaskets, remote, stainless
Usage: Promass 500, Promass 500 digital, sensor connection housing. Consists of: gasket EPDM for cover, gasket EPDM for housing/sensor.
-
Nr 73 Order code 71323058
Kit hous.gaskets, remote,stainless,-50oC
Usage: Promass 500, Promass 500 digital, sensor connection housing. Consists of: gasket FVMQ for cover, -50oC/-58oF, gasket FVMQ for housing/sensor, -50oC/-58oF.
-
-
-
Nr 24 Order code 71185793
Kit cover,ultra compact,stainless 1.4301
Usage: Promag/Promass 100, Promag/Promass 500 digital, sensor connection housing. Consists of: cover stainless 1.4301, gasket EPDM for cover.
-
Nr 24 Order code 71323060
Kit cover, ultra compact, 1.4301, -50oC
Usage: Promass 500 digital, sensor connection housing. Consists of: cover stainless 1.4301, gasket FVMQ for cover, -50oC/-58oF.
-
-
-
Nr 73 Order code 71185799
Kit hous.gaskets,ultra compact,stainless
Usage: Promass 100, Promass 500 digital, sensor connection housing. Consists of: gasket EPDM for cover, gasket EPDM for housing/sensor.
-
Nr 73 Order code 71323062
Kit housing gasket, ultra compact, -50oC
Usage: Promass 500 digital, sensor connection housing stainless. Consists of: gasket FVMQ for cover, -50oC/-58oF, gasket FVMQ for housing/sensor, -50oC/-58oF.
-
-
-
Nr 24 Order code 71323063
Kit cover, remote, cast, Ex
Usage: Promag/Promass 500, Promag/Promass/Prosonic Flow/t-mass 500 digital, sensor connection housing. Consists of: cover cast, O-Ring 120,2x3,53 HNBR.
-
Nr 24 Order code 71323064
Kit cover, remote, cast, -50oC, Ex
Usage: Promass 500, Promass/Prosonic Flow/t-mass 500digital, sensor connection housing. Consists of: cover cast, O-Ring 120,2x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 73 Order code 71323065
Kit housing gaskets, remote, cast, Ex
Usage: Promass 500, Promass/Prosonic Flow/t-mass 500digital, sensor connection housing. Consists of: O-Ring 120,2x3,53 HNBR for cover, O-Ring 88,50x3,53HNBR for housing/sensor
-
Nr 73 Order code 71323066
Kit housing gaskets,remote,cast,-50oC,Ex
Usage: Promass 500, Promass/Prosonic Flow/t-mass 500digital, sensor connection housing. Consists of: O-Ring 120,2x3,53 FVMQ for cover, -50oC/-58oF, O-Ring 88,50x3,53 FVMQ for hous./sensor, -50oC/-58oF.
-
-
-
Nr 71 Order code 71323071
Kit interface gaskets, 300/500
Usage: Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing/sensor or transmitter housing/wall mount. Consists of: 5x O-Ring 88,50x3,53 HNBR for interface.
-
Nr 71 Order code 71323072
Kit interface gaskets, 300/500, -50oC
Usage: Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing/sensor or transmitter housing/wall mount. Consists of: O-Ring 88,50x3,53 FVMQ for interface, -50oC/-58oF.
-
-
-
Nr 11 Order code 71323081
Kit protective cover option A,300/500,Ex
Usage: transmitter housing Alu/cast, connection compartment. Option A = HART, PROFIBUS PA, PROFIBUS DP, Modbus RS485, FOUNDATION Fieldbus. Consists of: Connection compartment protective cover, display carrier, 2x screw M4x10.
-
Nr 11 Order code 71323082
Kit protective cover option B,300/500,Ex
Usage: transmitter housing Alu/cast, connection compartment. Option B = EtherNet, PROFINET. Consists of: Connection compartment protective cover, display carrier, 2x screw M4x10.
-
-
-
Nr 13 Order code 71276494
Kit securing clamp, screw
Usage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Sensor housing: Promag 400(C), (C) = generation index C, Promag/Promass 500, Promag/Promass/Prosonic Flow/t-mass 500 digital. Consists of: cover clamp, screw M4x16.
-
-
-
Nr 82 Order code 71228792
Kit display protec., 400(C)/500 digital
Usage: Promag 400(C) = generation index C, Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing Alu. Consists of: display protection 1.4301, installation material.
-
-
-
Nr 87 Order code 71343504
Kit weather protection cover,500 digital
Usage: Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing. Consists of: weather protection cover 4404.
-
Nr 87 Order code 71343505
Kit weather protection cover, 300/500
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing. Consists of: weather protection cover 4404, installation material.
-
-
-
Order code 71346427
Pipe Mounting kit Transmitter 500digital
-
Order code 71346428
Pipe Mounting kit Transmitter 500
-
Order code 71351317
Kit wireless antenna extended range
Consists of: Connection cable in the transmitter, Ex cable entry for antenna, 1.5m cable, antenna, angle with union nut.
-
Order code 71392563
Kit Sensor holder
Usage: Promass A, 8A2B, 8A3C, 8A5C. Consists of: 1x sensor holder 1.4404 3x holder bracket 1.4404 2x screw M8x50 INOX A4 2x spring washer M8 INOX A4.
-
Order code 8X5BXX-
-
Order code DK8013-
Promass 500, sensor cable set
Connection Cable (analog and digital) between Sensor Junction Housing and Transmitter for Remote Devices of Proline 500.
-
Order code DK8003-
-
Order code XPRFID-
-
-
Predecessor